10.0
CRITICAL
CVE-2016-9343
Rockwell Automation Logix5000 Programmable Automation Controller Stack BufferOverflow/Remote Code Execution (RCE) and Denial of Service (DoS)
Description

An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.

INFO

Published Date :

Feb. 13, 2017, 9:59 p.m.

Last Modified :

Feb. 3, 2022, 7:44 p.m.

Remotely Exploitable :

Yes !

Impact Score :

6.0

Exploitability Score :

3.9
Affected Products

The following products are affected by CVE-2016-9343 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Rockwellautomation softlogix_5800_controller_firmware
2 Rockwellautomation rslogix_emulate_5000_firmware
3 Rockwellautomation guardlogix_5570_controller_firmware
4 Rockwellautomation flexlogix_l34_controller_firmware
5 Rockwellautomation controllogix_l55_controller_firmware
6 Rockwellautomation controllogix_5570_redundant_controller_firmware
7 Rockwellautomation controllogix_5570_controller_firmware
8 Rockwellautomation controllogix_5560_redundant_controller_firmware
9 Rockwellautomation controllogix_5560_controller_firmware
10 Rockwellautomation 1769_compactlogix_l3x_controller_firmware
11 Rockwellautomation 1769_compactlogix_l23x_controller_firmware
12 Rockwellautomation 1769_compactlogix_5370_l3_controller_firmware
13 Rockwellautomation 1769_compactlogix_5370_l2_controller_firmware
14 Rockwellautomation 1769_compactlogix_5370_l1_controller_firmware
15 Rockwellautomation 1768_compactlogix_l4x_controller_firmware
16 Rockwellautomation 1768_compact_guardlogix_l4xs_controller_firmware
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2016-9343.

URL Resource
http://www.securityfocus.com/bid/95304 Third Party Advisory VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 Third Party Advisory US Government Resource

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2016-9343 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2016-9343 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Reanalysis by [email protected]

    Feb. 03, 2022

    Action Type Old Value New Value
    Removed CVSS V3 NIST AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
    Changed Reference Type https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 Broken Link https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 Third Party Advisory, US Government Resource
    Removed CWE NIST CWE-119
    Added CWE NIST CWE-787
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:softlogix_5800_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:softlogix_5800_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:softlogix_5800_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:softlogix_5800_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:softlogix_5800_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:softlogix_5800_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:rslogix_emulate_5000:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:rslogix_emulate_5000_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:rslogix_emulate_5000_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:rslogix_emulate_5000_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:rslogix_emulate_5000_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:rslogix_emulate_5000:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.017:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:guardlogix_5570_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.017:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:guardlogix_5570_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:flexlogix_l34_controller_firmware:16.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:flexlogix_l34_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:flexlogix_l34_controller_firmware:16.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:flexlogix_l34_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.022:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_l55_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:controllogix_l55_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_l55_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_l55_controller_firmware:16.022:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:controllogix_l55_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.055:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5570_redundant_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.055:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:controllogix_5570_redundant_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5570_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:controllogix_5570_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.055:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5560_redundant_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:controllogix_5560_redundant_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_redundant_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_redundant_controller_firmware:20.055:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:controllogix_5560_redundant_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.022:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5560_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:16.022:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:controllogix_5560_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:controllogix_5560_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.023:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_l3x_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:16.023:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l3x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1769_compactlogix_l3x_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_l23x_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_l23x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1769_compactlogix_l23x_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l3_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l3_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l3_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l3_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l3_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1769_compactlogix_5370_l3_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l2_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l2_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l2_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l2_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l2_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1769_compactlogix_5370_l2_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l1_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l1_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l1_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l1_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1769_compactlogix_5370_l1_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1769_compactlogix_5370_l1_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.025:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.016:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1768_compactlogix_l4x_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:16.025:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compactlogix_l4x_controller_firmware:20.016:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1768_compactlogix_l4x_controller:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1768_compact_guardlogix_l4xs_controller:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:rockwellautomation:1768_compact_guardlogix_l4xs_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compact_guardlogix_l4xs_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compact_guardlogix_l4xs_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compact_guardlogix_l4xs_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwellautomation:1768_compact_guardlogix_l4xs_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwellautomation:1768_compact_guardlogix_l4xs_controller:-:*:*:*:*:*:*:*
  • Reanalysis by [email protected]

    Jun. 28, 2017

    Action Type Old Value New Value
    Changed CVSS V3 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
  • Initial Analysis by [email protected]

    Mar. 16, 2017

    Action Type Old Value New Value
    Added CVSS V2 (AV:N/AC:L/Au:N/C:P/I:P/A:P)
    Added CVSS V3 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
    Changed Reference Type http://www.securityfocus.com/bid/95304 No Types Assigned http://www.securityfocus.com/bid/95304 Third Party Advisory, VDB Entry
    Changed Reference Type https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 No Types Assigned https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 Broken Link
    Added CWE CWE-119
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:softlogix_5800_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:softlogix_5800_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:rslogix_emulate_5000_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:rslogix_emulate_5000:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:20.017:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:guardlogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:guardlogix_5570_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:flexlogix_l34_controller_firmware:16.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:flexlogix_l34_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_l55_controller_firmware:16.022:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_l55_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:20.055:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_redundant_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5570_redundant_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5570_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5570_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.050:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_redundant_controller_firmware:20.055:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5560_redundant_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:16.022:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:controllogix_5560_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:controllogix_5560_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:16.023:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l3x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_l3x_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_l23x_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_l23x_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l3_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l3_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l2_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l2_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.010:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:20.013:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1769_compactlogix_5370_l1_controller_firmware:21.00:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1769_compactlogix_5370_l1_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.020:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:16.025:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:17.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compactlogix_l4x_controller_firmware:20.016:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1768_compactlogix_l4x_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:18.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:19.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.00:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.011:*:*:*:*:*:*:* *cpe:2.3:o:rockwell_automation:1768_compact_guardlogix_l4xs_controller_firmware:20.013:*:*:*:*:*:*:* OR cpe:2.3:h:rockwell_automation:1768_compact_guardlogix_l4xs_controller:-:*:*:*:*:*:*:*
  • CVE Modified by [email protected]

    Feb. 15, 2017

    Action Type Old Value New Value
    Added Reference http://www.securityfocus.com/bid/95304 [No Types Assigned]
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2016-9343 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2016-9343 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.15 }} 0.01%

score

0.50954

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability