CVE-2018-11447
"Siemens SCALANCE M875 CSRF Authentication Bypass"
Description
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.
INFO
Published Date :
June 26, 2018, 6:29 p.m.
Last Modified :
Oct. 9, 2019, 11:33 p.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.8
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2018-11447
.
URL | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf | Third Party Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2018-11447
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2018-11447
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Oct. 09, 2019
Action Type Old Value New Value Added CWE Siemens AG CWE-121 -
Initial Analysis by [email protected]
Aug. 24, 2018
Action Type Old Value New Value Added CVSS V2 Metadata Victim must voluntarily interact with attack mechanism Added CVSS V2 (AV:N/AC:M/Au:N/C:P/I:P/A:P) Added CVSS V3 AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf Third Party Advisory Added CWE CWE-352 Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m875_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:scalance_m875:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2018-11447
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2018-11447
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.06 }} 0.00%
score
0.21397
percentile