A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
INFO
Published Date :
July 23, 2018, 9:29 p.m.
Last Modified :
March 22, 2019, 5:29 p.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
3.6
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2018-11452
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2018-11452
.
URL | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf | Mitigation Patch Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf | Mitigation Patch Vendor Advisory |
https://www.securityfocus.com/bid/106221 |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2018-11452
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2018-11452
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Mar. 22, 2019
Action Type Old Value New Value Changed Description A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Removed Reference http://www.securityfocus.com/bid/106221 [Third Party Advisory, VDB Entry] Added Reference https://www.securityfocus.com/bid/106221 [No Types Assigned] -
Modified Analysis by [email protected]
Mar. 05, 2019
Action Type Old Value New Value Changed Reference Type http://www.securityfocus.com/bid/106221 No Types Assigned http://www.securityfocus.com/bid/106221 Third Party Advisory, VDB Entry Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf Mitigation, Vendor Advisory https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf Mitigation, Patch, Vendor Advisory Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf Mitigation, Patch, Vendor Advisory -
CVE Modified by [email protected]
Feb. 11, 2019
Action Type Old Value New Value Added Reference http://www.securityfocus.com/bid/106221 [No Types Assigned] -
CVE Modified by [email protected]
Jan. 09, 2019
Action Type Old Value New Value Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf [No Types Assigned] -
Initial Analysis by [email protected]
Oct. 03, 2018
Action Type Old Value New Value Added CVSS V2 (AV:N/AC:L/Au:N/C:N/I:N/A:C) Added CVSS V3 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf Mitigation, Vendor Advisory Added CWE CWE-20 Added CPE Configuration AND OR *cpe:2.3:o:siemens:dnp3_tcp_firmware:-:*:*:*:*:*:*:* *cpe:2.3:o:siemens:iec104_firmware:-:*:*:*:*:*:*:* *cpe:2.3:o:siemens:iec_61850_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.33 *cpe:2.3:o:siemens:modbus_tcp_firmware:-:*:*:*:*:*:*:* *cpe:2.3:o:siemens:profinet_io_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:en100:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:cp100_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 7.80 *cpe:2.3:o:siemens:cp200_firmware:-:*:*:*:*:*:*:* *cpe:2.3:o:siemens:cp300_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 7.80 OR cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2018-11452
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2018-11452
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.24 }} -0.10%
score
0.64052
percentile