A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
INFO
Published Date :
June 14, 2018, 4:29 p.m.
Last Modified :
Dec. 13, 2022, 5:15 p.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
2.7
Exploitability Score :
2.8
Affected Products
The following products are affected by CVE-2018-4848
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2018-4848
.
URL | Resource |
---|---|
http://www.securityfocus.com/bid/104494 | Third Party Advisory VDB Entry |
https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf | Third Party Advisory Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2018-4848
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2018-4848
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Dec. 13, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. -
CVE Modified by [email protected]
Dec. 13, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. -
CVE Modified by [email protected]
Jan. 16, 2020
Action Type Old Value New Value Changed Description A vulnerability has been identified in SCALANCE X-200 (All versions < V5.2.3), SCALANCE X-200 IRT (All versions < V5.4.1), SCALANCE X300 (All versions). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. -
CVE Modified by [email protected]
Oct. 09, 2019
Action Type Old Value New Value Added CWE Siemens AG CWE-80 -
CVE Modified by [email protected]
Nov. 27, 2018
Action Type Old Value New Value Changed Description A vulnerability has been identified in SCALANCE X-200 IRT (All versions < V5.4.1), SCALANCE X300 (All versions). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. A vulnerability has been identified in SCALANCE X-200 (All versions < V5.2.3), SCALANCE X-200 IRT (All versions < V5.4.1), SCALANCE X300 (All versions). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it. -
Initial Analysis by [email protected]
Aug. 14, 2018
Action Type Old Value New Value Added CVSS V2 Metadata Victim must voluntarily interact with attack mechanism Added CVSS V2 (AV:N/AC:M/Au:N/C:N/I:P/A:N) Added CVSS V3 AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N Changed Reference Type http://www.securityfocus.com/bid/104494 No Types Assigned http://www.securityfocus.com/bid/104494 Third Party Advisory, VDB Entry Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf Third Party Advisory, Vendor Advisory Added CWE CWE-79 Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_x-200_irt_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 5.4.1 OR cpe:2.3:h:siemens:scalance_x-200_irt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:h:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 5.2.3 OR cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:* -
CVE Modified by [email protected]
Jun. 21, 2018
Action Type Old Value New Value Added Reference http://www.securityfocus.com/bid/104494 [No Types Assigned]
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2018-4848
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2018-4848
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.06 }} 0.00%
score
0.23982
percentile