CVE-2018-7105
HPE iLO Command Injection Vulnerability
Description
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information.
INFO
Published Date :
Sept. 27, 2018, 6:29 p.m.
Last Modified :
Nov. 21, 2024, 4:11 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
1.2
Public PoC/Exploit Available at Github
CVE-2018-7105 has a 1 public PoC/Exploit
available at Github.
Go to the Public Exploits
tab to see the list.
Affected Products
The following products are affected by CVE-2018-7105
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2018-7105
.
URL | Resource |
---|---|
http://www.securityfocus.com/bid/105425 | Third Party Advisory VDB Entry |
http://www.securitytracker.com/id/1041649 | Third Party Advisory VDB Entry |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us | Mitigation Vendor Advisory |
http://www.securityfocus.com/bid/105425 | Third Party Advisory VDB Entry |
http://www.securitytracker.com/id/1041649 | Third Party Advisory VDB Entry |
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us | Mitigation Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
PCILeech HP iLO4 Service
Python
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2018-7105
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2018-7105
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CWE Remap by [email protected]
Oct. 03, 2019
Action Type Old Value New Value Changed CWE CWE-254 NVD-CWE-noinfo -
Initial Analysis by [email protected]
Dec. 19, 2018
Action Type Old Value New Value Added CVSS V2 (AV:N/AC:L/Au:S/C:C/I:C/A:C) Added CVSS V3 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Changed Reference Type http://www.securitytracker.com/id/1041649 No Types Assigned http://www.securitytracker.com/id/1041649 Third Party Advisory, VDB Entry Changed Reference Type http://www.securityfocus.com/bid/105425 No Types Assigned http://www.securityfocus.com/bid/105425 Third Party Advisory, VDB Entry Changed Reference Type https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us No Types Assigned https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03866en_us Mitigation, Vendor Advisory Added CWE CWE-254 Added CPE Configuration AND OR *cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 1.35 OR cpe:2.3:h:hp:gen_10_servers:-:*:*:*:*:*:*:* cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hp:integrated_lights-out_3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 1.90 *cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.61 OR cpe:2.3:h:hp:integrated_lights-out:-:*:*:*:*:*:*:* -
CVE Modified by [email protected]
Oct. 18, 2018
Action Type Old Value New Value Changed Description A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code. A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to disclosure of information. -
CVE Modified by [email protected]
Oct. 02, 2018
Action Type Old Value New Value Added Reference http://www.securityfocus.com/bid/105425 [No Types Assigned] -
CVE Modified by [email protected]
Sep. 28, 2018
Action Type Old Value New Value Added Reference http://www.securitytracker.com/id/1041649 [No Types Assigned]
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2018-7105
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2018-7105
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.53 }} -0.23%
score
0.77396
percentile