CVE-2019-10934
Siemens TIA Portal Arbitrary Code Execution Vulnerability
Description
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
INFO
Published Date :
Jan. 16, 2020, 4:15 p.m.
Last Modified :
Nov. 21, 2024, 4:20 a.m.
Source :
[email protected]
Remotely Exploitable :
No
Impact Score :
5.9
Exploitability Score :
1.8
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2019-10934
.
URL | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf | Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2019-10934
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2019-10934
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Aug. 10, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
Aug. 10, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
Jun. 14, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
May. 20, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
May. 20, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
Modified Analysis by [email protected]
Apr. 24, 2022
Action Type Old Value New Value Changed CPE Configuration OR *cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:* versions up to (including) 14 *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_1:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_2:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_3:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:* OR *cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:* versions from (including) 14 up to (including) 17 -
CVE Modified by [email protected]
Dec. 14, 2021
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
Dec. 14, 2021
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions < V14 SP1 Update 10), TIA Portal V15 (All versions < V15 SP1 Update 4), TIA Portal V16 (All versions < V16 Update 1). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
Jan. 12, 2021
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 4), TIA Portal V16 (All versions < V16 Update 1). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions < V14 SP1 Update 10), TIA Portal V15 (All versions < V15 SP1 Update 4), TIA Portal V16 (All versions < V16 Update 1). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
CVE Modified by [email protected]
Apr. 14, 2020
Action Type Old Value New Value Changed Description A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Upd 4), TIA Portal V16 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 4), TIA Portal V16 (All versions < V16 Update 1). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known. -
Initial Analysis by [email protected]
Jan. 22, 2020
Action Type Old Value New Value Added CVSS V2 NIST (AV:L/AC:L/Au:N/C:C/I:C/A:C) Added CVSS V3.1 NIST AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf Vendor Advisory Added CWE NIST CWE-22 Added CPE Configuration OR *cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:* versions up to (including) 14 *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_1:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_2:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:update_3:*:*:*:*:*:* *cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2019-10934
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2019-10934
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.04 }} 0.00%
score
0.07978
percentile