7.5
HIGH
CVE-2019-6575
Siemens OPC UA Deserialization Denial of Service (DoS) Vulnerability
Description

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.

INFO

Published Date :

April 17, 2019, 2:29 p.m.

Last Modified :

Nov. 21, 2024, 4:46 a.m.

Remotely Exploitable :

Yes !

Impact Score :

3.6

Exploitability Score :

3.9
Affected Products

The following products are affected by CVE-2019-6575 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens simatic_s7-1500_software_controller_firmware
2 Siemens simatic_wincc
3 Siemens simatic_s7-1500_firmware
4 Siemens simatic_s7-1500f_firmware
5 Siemens simatic_ipc_diagmonitor_firmware
6 Siemens sinec_nms
7 Siemens simatic_s7-1500_software_controller
8 Siemens simatic_rf188c_firmware
9 Siemens simatic_wincc_oa
10 Siemens sinema_server
11 Siemens simatic_s7-1500t_firmware
12 Siemens simatic_wincc_runtime_advanced
13 Siemens simatic_cp_443-1_opc_ua_firmware
14 Siemens telecontrol_server_basic
15 Siemens simatic_hmi_comfort_outdoor_panels_firmware
16 Siemens sinumerik_opc_ua_server
17 Siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware
18 Siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware
19 Siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware
20 Siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware
21 Siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware
22 Siemens simatic_rf600r_firmware
23 Siemens simatic_s7-1500s_firmware
24 Siemens simatic_cp443-1_opc_ua_firmware
25 Siemens simatic_et_200_open_controller_cpu_1515sp_pc2_firmware
26 Siemens simatic_net_pc_software_firmware
27 Siemens opc_unified_architecture
28 Siemens simatic_wincc_runtime_comfort
29 Siemens simatic_wincc_runtime_hsp_comfort
30 Siemens simatic_wincc_runtime_mobile
31 Siemens sinec-nms
32 Siemens simatic_ipc_diagmonitor
33 Siemens simatic_hmi_comfort_outdoor_panels
34 Siemens simatic_rf188c
35 Siemens simatic_s7-1500
36 Siemens simatic_s7-1500t
37 Siemens simatic_s7-1500f
38 Siemens simatic_hmi_ktp_mobile_panels_ktp400f
39 Siemens simatic_hmi_ktp_mobile_panels_ktp700
40 Siemens simatic_hmi_ktp_mobile_panels_ktp700f
41 Siemens simatic_hmi_ktp_mobile_panels_ktp900
42 Siemens simatic_hmi_ktp_mobile_panels_ktp900f
43 Siemens simatic_rf600r
44 Siemens simatic_s7-1500s
45 Siemens simatic_cp443-1_opc_ua
46 Siemens simatic_et_200_open_controller_cpu_1515sp_pc2
47 Siemens simatic_net_pc_software
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2019-6575.

URL Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2019-6575 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2019-6575 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf
  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Modified Analysis by [email protected]

    Oct. 06, 2022

    Action Type Old Value New Value
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.7 OR cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*
    Changed CPE Configuration OR *cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* versions up to (including) 2.5 *cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:* versions up to (excluding) 3.15-p018 *cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:* versions up to (excluding) 2.1 *cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* OR *cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* versions up to (including) 2.5 *cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:* versions up to (excluding) 3.15-p018 *cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:* versions up to (excluding) 1.0 *cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:* *cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:* versions up to (excluding) 2.1 *cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* versions up to (excluding) 3.1.1
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 15.1 *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
  • CVE Modified by [email protected]

    Aug. 10, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
  • CVE Modified by [email protected]

    Aug. 10, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
  • CVE Modified by [email protected]

    Apr. 12, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
  • CVE Modified by [email protected]

    Apr. 12, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
  • CVE Modified by [email protected]

    Feb. 09, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
  • Modified Analysis by [email protected]

    Oct. 16, 2020

    Action Type Old Value New Value
    Removed CVSS V3 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
    Removed CWE NIST CWE-20
    Added CWE NIST CWE-755
  • CVE Modified by [email protected]

    Mar. 10, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • CVE Modified by [email protected]

    Feb. 11, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1 < V16), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • CVE Modified by [email protected]

    Jan. 16, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP443-1 OPC UA (incl. SIPLUS NET variants) (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • CVE Modified by [email protected]

    Oct. 09, 2019

    Action Type Old Value New Value
    Added CWE Siemens AG CWE-248
  • CVE Modified by [email protected]

    Jul. 11, 2019

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions >= V2.5), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • CVE Modified by [email protected]

    Jun. 12, 2019

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions >= V2.5), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions >= V2.5), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • CVE Modified by [email protected]

    May. 14, 2019

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions >= V2.5), SIMATIC S7-1500 Software Controller (All versions >= V2.5), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Comfort (All versions), SIMATIC WinCC Runtime HSP Comfort (All versions), SIMATIC WinCC Runtime Mobile (All versions), SINEC-NMS (All versions), SINEMA Server (All versions), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known. A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions), SIMATIC RF600R (All versions), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions >= V2.5), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.
  • Initial Analysis by [email protected]

    Apr. 18, 2019

    Action Type Old Value New Value
    Added CVSS V2 (AV:N/AC:L/Au:N/C:N/I:N/A:C)
    Added CVSS V3 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
    Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf Vendor Advisory
    Added CWE CWE-20
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5 OR cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*
    Added CPE Configuration OR *cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* versions up to (including) 2.5 *cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:* versions up to (excluding) 3.15-p018 *cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:* versions up to (excluding) 2.1 *cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5 OR cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5 OR cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.5 OR cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2019-6575 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2019-6575 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.18 }} -0.03%

score

0.55276

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability