CVE-2019-6842
Modicon PLC Denial of Service Exceptional Condition Handling Vulnerability
Description
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
INFO
Published Date :
Oct. 29, 2019, 7:15 p.m.
Last Modified :
Nov. 21, 2024, 4:47 a.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
                                            The following products are affected by CVE-2019-6842
                                            vulnerability.
                                            Even if cvefeed.io is aware of the exact versions of the
                                            products
                                            that
                                            are
                                            affected, the information is not represented in the table below.
                                        
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source | 
|---|---|---|---|---|---|---|
| CVSS 2.0 | MEDIUM | [email protected] | ||||
| CVSS 3.1 | MEDIUM | [email protected] | 
References to Advisories, Solutions, and Tools
                                            Here, you will find a curated list of external links that provide in-depth
                                            information, practical solutions, and valuable tools related to
                                            CVE-2019-6842.
                                        
| URL | Resource | 
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ | Vendor Advisory | 
| https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ | Vendor Advisory | 
CWE - Common Weakness Enumeration
            While CVE identifies
            specific instances of vulnerabilities, CWE categorizes the common flaws or
            weaknesses that can lead to vulnerabilities. CVE-2019-6842 is
            associated with the following CWEs:
        
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
            (CAPEC)
            stores attack patterns, which are descriptions of the common attributes and
            approaches employed by adversaries to exploit the CVE-2019-6842
            weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
			The following list is the news that have been mention
			CVE-2019-6842 vulnerability anywhere in the article.
		
                The following table lists the changes that have been made to the
                CVE-2019-6842 vulnerability over time.
            
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
- 
                            CVE Modified by af854a3a-2127-422b-91ae-364da2661108Nov. 21, 2024 Action Type Old Value New Value Added Reference https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ 
- 
                            CVE Modified by [email protected]May. 14, 2024 Action Type Old Value New Value 
- 
                            Reanalysis by [email protected]Feb. 03, 2022 Action Type Old Value New Value Changed CPE Configuration AND OR *cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:se:modicon_m340:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* 
- 
                            CPE Deprecation Remap by [email protected]Jan. 31, 2022 Action Type Old Value New Value Changed CPE Configuration OR *cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* OR *cpe:2.3:h:se:modicon_m340:-:*:*:*:*:*:*:* 
- 
                            CPE Deprecation Remap by [email protected]Jan. 31, 2022 Action Type Old Value New Value Changed CPE Configuration OR *cpe:2.3:h:se:modicon_m340:-:*:*:*:*:*:*:* OR *cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* 
- 
                            Modified Analysis by [email protected]Sep. 14, 2021 Action Type Old Value New Value Changed Reference Type https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ No Types Assigned https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ Vendor Advisory 
- 
                            CPE Deprecation Remap by [email protected]Aug. 19, 2021 Action Type Old Value New Value Changed CPE Configuration OR *cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* OR *cpe:2.3:h:se:modicon_m340:-:*:*:*:*:*:*:* 
- 
                            CVE Modified by [email protected]Apr. 19, 2021 Action Type Old Value New Value Changed Description A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol. A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol. Removed Reference https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02 [Vendor Advisory] Added Reference https://www.se.com/ww/en/download/document/SEVD-2019-281-02/ [No Types Assigned] Removed CWE Schneider Electric SE CWE-248 Added CWE Schneider Electric SE CWE-755 Removed CWE Reason CWE-248 / Assessment performed prior to CVMAP efforts 
- 
                            Initial Analysis by [email protected]Nov. 01, 2019 Action Type Old Value New Value Added CVSS V2 NIST (AV:N/AC:L/Au:S/C:N/I:N/A:P) Added CVSS V3.1 NIST AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H Changed Reference Type https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02 No Types Assigned https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02 Vendor Advisory Added CWE NIST CWE-755 Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:modicon_bmxcra_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:modicon_bmxcra:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:modicon_140cra_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:modicon_140cra:-:*:*:*:*:*:*:* 
Vulnerability Scoring Details
Base CVSS Score: 4.9
Base CVSS Score: 4
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.38 }} -0.07%
score
0.56627
percentile
 
                         
                         
                         
                                             
                                            