7.5
HIGH
CVE-2021-22788
Modicon HTTP Request Denial of Service
Description

A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)

INFO

Published Date :

Feb. 11, 2022, 6:15 p.m.

Last Modified :

April 10, 2024, 12:28 p.m.

Remotely Exploitable :

Yes !

Impact Score :

3.6

Exploitability Score :

3.9
Affected Products

The following products are affected by CVE-2021-22788 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Schneider-electric bmxnoe0100_firmware
2 Schneider-electric bmxnoe0110_firmware
3 Schneider-electric 140cpu65150_firmware
4 Schneider-electric 140noc77101_firmware
5 Schneider-electric tsxp574634_firmware
6 Schneider-electric tsxp575634_firmware
7 Schneider-electric tsxp576634_firmware
8 Schneider-electric tsxety4103_firmware
9 Schneider-electric tsxety5103_firmware
10 Schneider-electric bmxnoc0401_firmware
11 Schneider-electric modicon_m340_bmxp342020_firmware
12 Schneider-electric bmxnor0200h_rtu_firmware
13 Schneider-electric 140noe771x1_firmware
14 Schneider-electric 140noc78x00_firmware
15 Schneider-electric modicon_m340_bmxp342020
16 Schneider-electric bmxnoc0401
17 Schneider-electric bmxnoe0100
18 Schneider-electric bmxnoe0110
19 Schneider-electric 140cpu65150
20 Schneider-electric tsxp574634
21 Schneider-electric tsxp575634
22 Schneider-electric tsxp576634
23 Schneider-electric tsxety4103
24 Schneider-electric tsxety5103
25 Schneider-electric 140noc77101
26 Schneider-electric bmxnor0200h_rtu
27 Schneider-electric 140noe771x1
28 Schneider-electric 140noc78x00
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2021-22788.

URL Resource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02 Patch Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2021-22788 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2021-22788 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Initial Analysis by [email protected]

    Feb. 23, 2022

    Action Type Old Value New Value
    Added CVSS V2 NIST (AV:N/AC:L/Au:N/C:N/I:N/A:P)
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
    Changed Reference Type https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02 No Types Assigned https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02 Patch, Vendor Advisory
    Added CWE NIST CWE-787
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:bmxp342020_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.40 OR cpe:2.3:h:schneider-electric:bmxp342020:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:bmxnor0200h_rtu_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:bmxnor0200h_rtu:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:tsxp574634_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:tsxp574634:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:tsxp575634_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:tsxp575634:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:tsxp576634_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:tsxp576634:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:140cpu65150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:140noe771x1_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:140noe771x1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:140noc78x00_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:140noc78x00:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:140noc77101_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:140noc77101:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:tsxety4103_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:tsxety4103:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:tsxety5103_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:schneider-electric:tsxety5103:-:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2021-22788 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2021-22788 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.11 }} 0.00%

score

0.43740

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability