CVE-2021-22812
APC NMC2/X2 Cross-Site Scripting
Description

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

INFO

Published Date :

Jan. 28, 2022, 8:15 p.m.

Last Modified :

Nov. 21, 2024, 5:50 a.m.

Remotely Exploitable :

Yes !

Impact Score :

2.7

Exploitability Score :

2.8
Affected Products

The following products are affected by CVE-2021-22812 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Schneider-electric network_management_card_2_firmware
2 Schneider-electric network_management_card_3_firmware
3 Schneider-electric galaxy_3500
4 Schneider-electric network_management_card_2
5 Schneider-electric single-phase_symmetra
6 Schneider-electric smart-ups
7 Schneider-electric ap9922_battery_management_system
8 Schneider-electric apc_rack_power_distribution_units
9 Schneider-electric galaxy_g7x
10 Schneider-electric galaxy_g9kchu
11 Schneider-electric galaxy_gcxsa
12 Schneider-electric galaxy_gfc
13 Schneider-electric galaxy_gvmsa
14 Schneider-electric galaxy_gvmts
15 Schneider-electric galaxy_gvxts
16 Schneider-electric galaxy_rpp_grppip2x84
17 Schneider-electric gutor_gvx
18 Schneider-electric gutor_sxw
19 Schneider-electric netbotz_nbrk0250
20 Schneider-electric pd40e5ek20-m
21 Schneider-electric pd40f6fk1-m
22 Schneider-electric pd40g6fk1-m
23 Schneider-electric pd40h5ek20-m
24 Schneider-electric pd40l6fk1-m
25 Schneider-electric pd60f6fk1
26 Schneider-electric pd60g6fk1
27 Schneider-electric pd60l6fk1
28 Schneider-electric pdpb150g6f
29 Schneider-electric pdpm138h-5u
30 Schneider-electric pdpm138h-r
31 Schneider-electric pdpm144f
32 Schneider-electric pdpm150g6f
33 Schneider-electric pdpm150l6f
34 Schneider-electric pdpm175g6h
35 Schneider-electric pdpm277h
36 Schneider-electric pdpm288g6h
37 Schneider-electric pdpm72f-5u
38 Schneider-electric pdrppnx10
39 Schneider-electric pdrppnx10m
40 Schneider-electric pmm400-ala
41 Schneider-electric pmm400-alax
42 Schneider-electric pmm400-cub
43 Schneider-electric pmm500-ala
44 Schneider-electric pmm500-alax
45 Schneider-electric pmm500-cub
46 Schneider-electric rack_automatic_transfer_switches
47 Schneider-electric symmetra_px_100
48 Schneider-electric symmetra_px_160
49 Schneider-electric symmetra_px_20
50 Schneider-electric symmetra_px_250
51 Schneider-electric symmetra_px_40
52 Schneider-electric symmetra_px_48
53 Schneider-electric symmetra_px_500
54 Schneider-electric symmetra_px_96
55 Schneider-electric network_management_card_3
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2021-22812.

URL Resource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03 Mitigation Vendor Advisory
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03 Mitigation Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2021-22812 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2021-22812 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03
  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Initial Analysis by [email protected]

    Feb. 04, 2022

    Action Type Old Value New Value
    Added CVSS V2 Metadata Victim must voluntarily interact with attack mechanism
    Added CVSS V2 NIST (AV:N/AC:M/Au:N/C:N/I:P/A:N)
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
    Changed Reference Type https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03 No Types Assigned https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03 Mitigation, Vendor Advisory
    Added CWE NIST CWE-79
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* versions up to (including) 6.9.8 OR cpe:2.3:h:schneider-electric:galaxy_3500:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:network_management_card_2:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:single-phase_symmetra:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:smart-ups:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:network_management_card_2_firmware:*:*:*:*:*:*:*:* versions up to (including) 6.9.6 OR cpe:2.3:h:schneider-electric:ap9922_battery_management_system:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:apc_rack_power_distribution_units:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_g7x:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_g9kchu:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_gcxsa:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_gfc:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_gvmsa:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_gvmts:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_gvxts:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:galaxy_rpp_grppip2x84:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:gutor_gvx:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:gutor_sxw:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:netbotz_nbrk0250:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:network_management_card_2:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd40e5ek20-m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd40f6fk1-m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd40g6fk1-m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd40h5ek20-m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd40l6fk1-m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd60f6fk1:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd60g6fk1:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pd60l6fk1:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpb150g6f:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm138h-5u:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm138h-r:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm144f:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm150g6f:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm150l6f:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm175g6h:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm277h:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm288g6h:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdpm72f-5u:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdrppnx10:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pdrppnx10m:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm400-ala:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm400-alax:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm400-cub:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm500-ala:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm500-alax:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:pmm500-cub:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:rack_automatic_transfer_switches:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_100:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_160:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_20:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_250:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_40:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_48:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_500:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:symmetra_px_96:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* versions up to (including) 1.4.2.1 OR cpe:2.3:h:schneider-electric:galaxy_3500:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:network_management_card_3:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:single-phase_symmetra:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:smart-ups:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:network_management_card_3_firmware:*:*:*:*:*:*:*:* versions up to (including) 1.4.0 OR cpe:2.3:h:schneider-electric:apc_rack_power_distribution_units:-:*:*:*:*:*:*:* cpe:2.3:h:schneider-electric:network_management_card_3:-:*:*:*:*:*:*:*
  • CVE Modified by [email protected]

    Jan. 28, 2022

    Action Type Old Value New Value
    Removed CWE Schneider Electric SE CWE-79
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2021-22812 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2021-22812 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.07 }} -0.00%

score

0.34452

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability