CVE-2021-26588
HPE 3PAR StoreServ, HPE Primera Storage, and HPE Alletra 9000 Storage Array Remote Code Execution Vulnerability
Description
A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware.
INFO
Published Date :
Oct. 11, 2021, 5:15 p.m.
Last Modified :
Nov. 21, 2024, 5:56 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2021-26588
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2021-26588
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2021-26588
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2021-26588
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst04191en_us -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
Initial Analysis by [email protected]
Oct. 18, 2021
Action Type Old Value New Value Added CVSS V2 NIST (AV:N/AC:L/Au:N/C:C/I:C/A:C) Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst04191en_us No Types Assigned https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst04191en_us Vendor Advisory Added CWE NIST NVD-CWE-noinfo Added CPE Configuration AND OR *cpe:2.3:o:hpe:3par_os:3.3.1_mp5_p156:*:*:*:*:*:*:* *cpe:2.3:o:hpe:3par_os:3.3.1_mu1:*:*:*:*:*:*:* *cpe:2.3:o:hpe:3par_os:3.3.1_mu2_p157:*:*:*:*:*:*:* *cpe:2.3:o:hpe:3par_os:3.3.2_ga_p_01:*:*:*:*:*:*:* OR cpe:2.3:h:hpe:3par_storeserv_10400:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_10800:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_20000:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_7200c:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_7400c:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_7440c:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_8000:-:*:*:*:*:*:*:* cpe:2.3:h:hpe:3par_storeserv_9000:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hpe:primera_630_firmware:*:*:*:*:*:*:*:* versions from (including) 4.0.0 up to (including) 4.3.3 OR cpe:2.3:h:hpe:primera_630:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hpe:primera_650_firmware:*:*:*:*:*:*:*:* versions from (including) 4.0.0 up to (including) 4.3.3 OR cpe:2.3:h:hpe:primera_650:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hpe:primera_670_firmware:*:*:*:*:*:*:*:* versions from (including) 4.0.0 up to (including) 4.3.3 OR cpe:2.3:h:hpe:primera_670:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hpe:alletra_9060_firmware:*:*:*:*:*:*:*:* versions from (including) 9.3.0 up to (including) 9.4.0 OR cpe:2.3:h:hpe:alletra_9060:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:hpe:alletra_9080_firmware:*:*:*:*:*:*:*:* versions from (including) 9.3.0 up to (including) 9.4.0 OR cpe:2.3:h:hpe:alletra_9080:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2021-26588
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2021-26588
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.30 }} 0.02%
score
0.70275
percentile