CVE-2021-31888
"Siemens Desigo and APOGEE BACnet and P2 Ethernet FTP Server Stack Based Buffer Overflow Vulnerability"
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
INFO
Published Date :
Nov. 9, 2021, 12:15 p.m.
Last Modified :
Nov. 21, 2024, 6:06 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.8
Affected Products
The following products are affected by CVE-2021-31888
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2021-31888
.
URL | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2021-31888
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2021-31888
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
Modified Analysis by [email protected]
May. 16, 2023
Action Type Old Value New Value Removed CPE Configuration OR *cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.1 *cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:* Removed CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* Added CPE Configuration OR *cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.4 *cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:p2_ethernet:*:*:* versions up to (excluding) 2.8.19 *cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:bacnet:*:*:* versions up to (excluding) 3.5.4 OR cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:p2_ethernet:*:*:* versions up to (excluding) 2.8.19 *cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:bacnet:*:*:* versions up to (excluding) 3.5.4 OR cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.5.4 OR cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.5.4 OR cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc00-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc00-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc00-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc00-u:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc001-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc001-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc12-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc12-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc22-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc22-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc22.1-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc22.1-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc36.1-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc36.1-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc50-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc50-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc64-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc64-u:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc100-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc100-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc128-u_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc128-u:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxc200-e.d_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxc200-e.d:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:desigo_pxm20-e_firmware:*:*:*:*:*:*:*:* versions from (including) 2.3 up to (excluding) 6.30.016 OR cpe:2.3:h:siemens:desigo_pxm20-e:-:*:*:*:*:*:*:* -
CVE Modified by [email protected]
May. 20, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) -
CVE Modified by [email protected]
Apr. 12, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) -
CVE Modified by [email protected]
Dec. 14, 2021
Action Type Old Value New Value Changed Description A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) -
Reanalysis by [email protected]
Nov. 12, 2021
Action Type Old Value New Value Changed CPE Configuration OR *cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.1 *cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:* versions up to (excluding) 4.1.1 *cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* OR *cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.1 *cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* -
Initial Analysis by [email protected]
Nov. 12, 2021
Action Type Old Value New Value Added CVSS V2 NIST (AV:N/AC:L/Au:S/C:P/I:P/A:P) Added CVSS V3.1 NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf Vendor Advisory Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf Vendor Advisory Added CWE NIST CWE-787 Added CPE Configuration OR *cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* *cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* versions up to (excluding) 2017.02.1 *cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:* versions up to (excluding) 4.1.1 *cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2021-31888
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2021-31888
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.30 }} 0.05%
score
0.66434
percentile