6.2
MEDIUM CVSS 3.1
CVE-2021-42744
Philips MRI 1.5T and 3T Information Exposure
Description

Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

INFO

Published Date :

Nov. 19, 2021, 7:15 p.m.

Last Modified :

April 2, 2026, 2:16 p.m.

Remotely Exploit :

No

Source :

20705f08-db8b-4497-8f94-7eea62317651
Affected Products

The following products are affected by CVE-2021-42744 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Philips mri_3t_firmware
2 Philips mri_1.5t_firmware
3 Philips mri_3t
4 Philips mri_1.5t
5 Philips mri_1.5t
6 Philips mri_3t
CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 2.0 LOW [email protected]
CVSS 3.1 MEDIUM [email protected]
CVSS 3.1 MEDIUM [email protected]
CVSS 4.0 MEDIUM 20705f08-db8b-4497-8f94-7eea62317651
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2021-42744.

URL Resource
https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01 Third Party Advisory US Government Resource
https://www.usa.philips.com/healthcare/about/customer-support/product-security Vendor Advisory
https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01 Third Party Advisory US Government Resource
https://www.usa.philips.com/healthcare/about/customer-support/product-security Vendor Advisory
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2021-42744 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2021-42744 weaknesses.

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2021-42744 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2021-42744 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by 20705f08-db8b-4497-8f94-7eea62317651

    Apr. 02, 2026

    Action Type Old Value New Value
    Changed Description Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access. Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
    Added CVSS V4.0 AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CWE CWE-552
    Added Reference https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01
    Added Reference https://www.usa.philips.com/healthcare/about/customer-support/product-security
  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01
    Added Reference https://www.usa.philips.com/healthcare/about/customer-support/product-security
  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Reanalysis by [email protected]

    Aug. 09, 2022

    Action Type Old Value New Value
    Removed CWE NIST CWE-668
    Added CWE NIST NVD-CWE-noinfo
  • Initial Analysis by [email protected]

    Nov. 23, 2021

    Action Type Old Value New Value
    Added CVSS V2 NIST (AV:L/AC:L/Au:N/C:P/I:N/A:N)
    Added CVSS V3.1 NIST AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
    Changed Reference Type https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01 No Types Assigned https://us-cert.cisa.gov/ics/advisories/icsma-21-313-01 Third Party Advisory, US Government Resource
    Changed Reference Type https://www.usa.philips.com/healthcare/about/customer-support/product-security No Types Assigned https://www.usa.philips.com/healthcare/about/customer-support/product-security Vendor Advisory
    Added CWE NIST CWE-668
    Added CPE Configuration AND OR *cpe:2.3:o:philips:mri_1.5t_firmware:*:*:*:*:*:*:*:* versions from (including) 5.0.0 up to (excluding) 6.0.0 OR cpe:2.3:h:philips:mri_1.5t:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:philips:mri_3t_firmware:*:*:*:*:*:*:*:* versions from (including) 5.0.0 up to (excluding) 6.0.0 OR cpe:2.3:h:philips:mri_3t:-:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.