8.1
HIGH
CVE-2022-25159
Mitsubishi Electric MELSEC Authentication Bypass Vulnerability
Description

Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack.

INFO

Published Date :

April 1, 2022, 11:15 p.m.

Last Modified :

June 2, 2022, 6:15 p.m.

Remotely Exploitable :

Yes !

Impact Score :

5.9

Exploitability Score :

2.2
Affected Products

The following products are affected by CVE-2022-25159 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Mitsubishielectric fx5uc-32mt\/d_firmware
2 Mitsubishielectric fx5uc-32mt\/dss_firmware
3 Mitsubishielectric fx5uc-32mt\/ds-ts_firmware
4 Mitsubishielectric fx5uc-32mt\/dss-ts_firmware
5 Mitsubishielectric fx5uc-32mr\/ds-ts_firmware
6 Mitsubishielectric fx5uj-24mt\/es_firmware
7 Mitsubishielectric fx5uj-40mt\/es_firmware
8 Mitsubishielectric fx5uj-60mt\/es_firmware
9 Mitsubishielectric fx5uj-24mr\/es_firmware
10 Mitsubishielectric fx5uj-40mr\/es_firmware
11 Mitsubishielectric fx5uj-60mr\/es_firmware
12 Mitsubishielectric fx5uj-24mt\/ess_firmware
13 Mitsubishielectric fx5uj-40mt\/ess_firmware
14 Mitsubishielectric fx5uj-60mt\/ess_firmware
15 Mitsubishielectric fx5uc_firmware
16 Mitsubishielectric fx5uj_firmware
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2022-25159.

URL Resource
https://jvn.jp/vu/JVNVU96577897/index.html Third Party Advisory
https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-04 Third Party Advisory US Government Resource
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-031_en.pdf Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2022-25159 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2022-25159 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • CVE Modified by [email protected]

    Jun. 02, 2022

    Action Type Old Value New Value
    Changed Description Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions and Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions allows a remote unauthenticated attacker to login to the product by replay attack. Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack.
  • Initial Analysis by [email protected]

    Apr. 08, 2022

    Action Type Old Value New Value
    Added CVSS V2 NIST (AV:N/AC:M/Au:N/C:P/I:P/A:P)
    Added CVSS V3.1 NIST AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
    Changed Reference Type https://jvn.jp/vu/JVNVU96577897/index.html No Types Assigned https://jvn.jp/vu/JVNVU96577897/index.html Third Party Advisory
    Changed Reference Type https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-04 No Types Assigned https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-04 Third Party Advisory, US Government Resource
    Changed Reference Type https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-031_en.pdf No Types Assigned https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-031_en.pdf Vendor Advisory
    Added CWE NIST CWE-294
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc-32mr\/ds-ts_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc-32mr\/ds-ts:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/d_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/d:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/dss:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-24mr\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-24mr\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-24mt\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/ess_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-24mt\/ess:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-40mr\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-40mr\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-40mt\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/ess_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-40mt\/ess:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-60mr\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-60mr\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/es_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-60mt\/es:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/ess_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj-60mt\/ess:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss-ts_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/dss-ts:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/ds-ts_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uc-32mt\/ds-ts:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:mitsubishielectric:fx5uj_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:mitsubishielectric:fx5uj:-:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.47 }} 0.05%

score

0.75859

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability