CVE-2022-29875
Siemens Healthcare Fusion Middleware Deserialization Vulnerability
Description
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.
INFO
Published Date :
June 1, 2022, 10:15 a.m.
Last Modified :
June 11, 2022, 12:45 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2022-29875
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2022-29875
.
URL | Resource |
---|---|
https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016 | Mitigation Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2022-29875
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2022-29875
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
Initial Analysis by [email protected]
Jun. 11, 2022
Action Type Old Value New Value Added CVSS V2 NIST (AV:N/AC:M/Au:N/C:C/I:C/A:C) Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016 No Types Assigned https://www.siemens-healthineers.com/support-documentation/cybersecurity/shsa-455016 Mitigation, Vendor Advisory Added CWE NIST CWE-502 Added CPE Configuration AND OR *cpe:2.3:o:siemens:biograph_horizon_pet\/ct_systems_firmware:*:*:*:*:*:*:*:* versions from (including) vj30 up to (excluding) vj30c-ud01 OR cpe:2.3:h:siemens:biograph_horizon_pet\/ct_systems:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va10b:*:*:*:*:*:*:* *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va12m:*:*:*:*:*:*:* *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va12s:*:*:*:*:*:*:* *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va20a:*:*:*:*:*:*:* *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va30a:*:*:*:*:*:*:* *cpe:2.3:o:siemens:magnetom_numaris_x_firmware:va31a:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:magnetom_numaris_x:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:mammomat_revelation_firmware:*:*:*:*:*:*:*:* versions from (including) vc20 up to (excluding) vc20d OR cpe:2.3:h:siemens:mammomat_revelation:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:naeotom_alpha_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:naeotom_alpha:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_x.cite_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_x.cite_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_x.cite_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_x.cite:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_x.creed_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_x.creed_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_x.creed_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_x.creed:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_go.all_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_go.all_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_go.all_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_go.all:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_go.now_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_go.now_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_go.now_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_go.now:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_go.open_pro_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_go.open_pro_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_go.open_pro_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_go.open_pro:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_go.sim_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_go.sim_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_go.sim_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_go.sim:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:somatom_go.up_firmware:*:*:*:*:*:*:*:* versions up to (excluding) va30 *cpe:2.3:o:siemens:somatom_go.up_firmware:va30:-:*:*:*:*:*:* *cpe:2.3:o:siemens:somatom_go.up_firmware:va40:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:somatom_go.up:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:symbia_e_firmware:*:*:*:*:*:*:*:* versions from (including) vb22 up to (excluding) vb22a-ud03 OR cpe:2.3:h:siemens:symbia_e:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:symbia_s_firmware:*:*:*:*:*:*:*:* versions from (including) vb22 up to (excluding) vb22a-ud03 OR cpe:2.3:h:siemens:symbia_s:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:symbia_evo_firmware:*:*:*:*:*:*:*:* versions from (including) vb22 up to (excluding) vb22a-ud03 OR cpe:2.3:h:siemens:symbia_evo:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:symbia_intevo_firmware:*:*:*:*:*:*:*:* versions from (including) vb22 up to (excluding) vb22a-ud03 OR cpe:2.3:h:siemens:symbia_intevo:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:symbia_t_firmware:*:*:*:*:*:*:*:* versions from (including) vb22 up to (excluding) vb22a-ud03 OR cpe:2.3:h:siemens:symbia_t:-:*:*:*:*:*:*:* Added CPE Configuration OR *cpe:2.3:a:siemens:symbia.net:*:*:*:*:*:*:*:* versions from (including) vb22 up to (including) vb22a-ud03 Added CPE Configuration OR *cpe:2.3:a:siemens:syngo.via:vb10:*:*:*:*:*:*:* *cpe:2.3:a:siemens:syngo.via:vb20:*:*:*:*:*:*:* *cpe:2.3:a:siemens:syngo.via:vb30:*:*:*:*:*:*:* *cpe:2.3:a:siemens:syngo.via:*:*:*:*:*:*:*:* versions from (including) vb40 up to (excluding) vb40b *cpe:2.3:a:siemens:syngo.via:vb40b:-:*:*:*:*:*:* *cpe:2.3:a:siemens:syngo.via:vb50:*:*:*:*:*:*:* *cpe:2.3:a:siemens:syngo.via:*:*:*:*:*:*:*:* versions from (including) vb60 up to (excluding) vb60b *cpe:2.3:a:siemens:syngo.via:vb60b:-:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2022-29875
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2022-29875
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.21 }} 0.01%
score
0.58940
percentile