6.5
MEDIUM
CVE-2022-30694
Oracle Web Services Login CSRF
Description

The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.

INFO

Published Date :

Nov. 8, 2022, 11:15 a.m.

Last Modified :

April 11, 2023, 10:15 a.m.

Remotely Exploitable :

Yes !

Impact Score :

3.6

Exploitability Score :

2.8
Affected Products

The following products are affected by CVE-2022-30694 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens simatic_drive_controller_cpu_1504d_tf_firmware
2 Siemens simatic_drive_controller_cpu_1507d_tf_firmware
3 Siemens simatic_s7-1500_cpu_1510sp_f-1_pn_firmware
4 Siemens simatic_s7-1500_cpu_1510sp-1_pn_firmware
5 Siemens simatic_s7-1500_cpu_1511-1_pn_firmware
6 Siemens simatic_s7-1500_cpu_1511c-1_pn_firmware
7 Siemens simatic_s7-1500_cpu_1511f-1_pn_firmware
8 Siemens simatic_s7-1500_cpu_1511t-1_pn_firmware
9 Siemens simatic_s7-1500_cpu_1511tf-1_pn_firmware
10 Siemens simatic_s7-1500_cpu_1512c-1_pn_firmware
11 Siemens simatic_s7-1500_cpu_1512sp_f-1_pn_firmware
12 Siemens simatic_s7-1500_cpu_1512sp-1_pn_firmware
13 Siemens simatic_s7-1500_cpu_1513-1_pn_firmware
14 Siemens simatic_s7-1500_cpu_1513f-1_pn_firmware
15 Siemens simatic_s7-1500_cpu_1513r-1_pn_firmware
16 Siemens simatic_s7-1500_cpu_1515-2_pn_firmware
17 Siemens simatic_s7-1500_cpu_1515f-2_pn_firmware
18 Siemens simatic_s7-1500_cpu_1515r-2_pn_firmware
19 Siemens simatic_s7-1500_cpu_1515t-2_pn_firmware
20 Siemens simatic_s7-1500_cpu_1515tf-2_pn_firmware
21 Siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware
22 Siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware
23 Siemens simatic_s7-1500_cpu_1516t-3_pn\/dp_firmware
24 Siemens simatic_s7-1500_cpu_1516tf-3_pn\/dp_firmware
25 Siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware
26 Siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware
27 Siemens simatic_s7-1500_cpu_1517h-3_pn_firmware
28 Siemens simatic_s7-1500_cpu_1517t-3_pn\/dp_firmware
29 Siemens simatic_s7-1500_cpu_1517tf-3_pn\/dp_firmware
30 Siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware
31 Siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware
32 Siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_mfp_firmware
33 Siemens simatic_s7-1500_cpu_1518hf-4_pn_firmware
34 Siemens simatic_s7-1500_cpu_1518t-4_pn\/dp_firmware
35 Siemens simatic_s7-1500_cpu_1518tf-4_pn\/dp_firmware
36 Siemens simatic_s7-1500_cpu_s7-1518-4_pn\/dp_odk_firmware
37 Siemens simatic_s7-1500_cpu_s7-1518f-4_pn\/dp_odk_firmware
38 Siemens siplus_et_200sp_cpu_1510sp_f-1_pn_firmware
39 Siemens siplus_et_200sp_cpu_1510sp_f-1_pn_rail_firmware
40 Siemens siplus_et_200sp_cpu_1510sp-1_pn_firmware
41 Siemens siplus_et_200sp_cpu_1510sp-1_pn_rail_firmware
42 Siemens siplus_et_200sp_cpu_1512sp_f-1_pn_firmware
43 Siemens siplus_et_200sp_cpu_1512sp_f-1_pn_rail_firmware
44 Siemens siplus_et_200sp_cpu_1512sp-1_pn_firmware
45 Siemens siplus_et_200sp_cpu_1512sp-1_pn_rail_firmware
46 Siemens siplus_s7-1500_cpu_1511-1_pn_firmware
47 Siemens siplus_s7-1500_cpu_1511-1_pn_t1_rail_firmware
48 Siemens siplus_s7-1500_cpu_1511-1_pn_tx_rail_firmware
49 Siemens siplus_s7-1500_cpu_1511f-1_pn_firmware
50 Siemens siplus_s7-1500_cpu_1513-1_pn_firmware
51 Siemens siplus_s7-1500_cpu_1513f-1_pn_firmware
52 Siemens siplus_s7-1500_cpu_1515f-2_pn_firmware
53 Siemens siplus_s7-1500_cpu_1515f-2_pn_rail_firmware
54 Siemens siplus_s7-1500_cpu_1515f-2_pn_t2_rail_firmware
55 Siemens siplus_s7-1500_cpu_1515r-2_pn_firmware
56 Siemens siplus_s7-1500_cpu_1515r-2_pn_tx_rail_firmware
57 Siemens siplus_s7-1500_cpu_1516-3_pn\/dp_firmware
58 Siemens siplus_s7-1500_cpu_1516-3_pn\/dp_rail_firmware
59 Siemens siplus_s7-1500_cpu_1516-3_pn\/dp_tx_rail_firmware
60 Siemens siplus_s7-1500_cpu_1516f-3_pn\/dp_firmware
61 Siemens siplus_s7-1500_cpu_1516f-3_pn\/dp_rail_firmware
62 Siemens siplus_s7-1500_cpu_1517h-3_pn_firmware
63 Siemens siplus_s7-1500_cpu_1518-4_pn\/dp_firmware
64 Siemens siplus_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware
65 Siemens siplus_s7-1500_cpu_1518f-4_pn\/dp_firmware
66 Siemens simatic_wincc
67 Siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware
68 Siemens simatic_s7-plcsim_advanced_firmware
69 Siemens siplus_s7-1500_cpu_1518hf-4_pn_firmware
70 Siemens simatic_wincc_runtime
71 Siemens simatic_s7-1200_cpu_1211c_firmware
72 Siemens simatic_s7-1200_cpu_1212c_firmware
73 Siemens simatic_s7-1200_cpu_1214c_firmware
74 Siemens simatic_s7-1200_cpu_1215c_firmware
75 Siemens simatic_s7-1200_cpu_1217c_firmware
76 Siemens simatic_s7-1500_cpu_1518_firmware
77 Siemens simatic_s7-1500_cpu_1511c_firmware
78 Siemens simatic_s7-1500_cpu_1512c_firmware
79 Siemens simatic_s7-plcsim_advanced
80 Siemens simatic_s7-1500_software_controller
81 Siemens simatic_s7-400_pn\/dp_v6_firmware
82 Siemens simatic_s7-400_pn\/dp_v7_firmware
83 Siemens simatic_pcs_firmware
84 Siemens simatic_s7-1200_cpu_1212fc_firmware
85 Siemens simatic_s7-1200_cpu_1214_fc_firmware
86 Siemens simatic_s7-1200_cpu_1214fc_firmware
87 Siemens simatic_s7-1200_cpu_1215_fc_firmware
88 Siemens simatic_s7-1200_cpu_1215fc_firmware
89 Siemens simatic_s7-1200_cpu_12_1211c_firmware
90 Siemens simatic_s7-1200_cpu_12_1212c_firmware
91 Siemens simatic_s7-1200_cpu_12_1212fc_firmware
92 Siemens simatic_s7-1200_cpu_12_1214c_firmware
93 Siemens simatic_s7-1200_cpu_12_1214fc_firmware
94 Siemens simatic_s7-1200_cpu_12_1215c_firmware
95 Siemens simatic_s7-1200_cpu_12_1215fc_firmware
96 Siemens simatic_s7-1200_cpu_12_1217c_firmware
97 Siemens simatic_s7-1500_cpu_1507s_firmware
98 Siemens simatic_s7-1500_cpu_1507s_f_firmware
99 Siemens simatic_s7-1500_cpu_1508s_firmware
100 Siemens simatic_s7-1500_cpu_1508s_f_firmware
101 Siemens simatic_s7-1500_cpu_1510sp_firmware
102 Siemens simatic_s7-1500_cpu_1510sp-1_firmware
103 Siemens simatic_s7-1500_cpu_1511-1_firmware
104 Siemens simatic_s7-1500_cpu_1511c-1_firmware
105 Siemens simatic_s7-1500_cpu_1511f-1_firmware
106 Siemens simatic_s7-1500_cpu_1511t-1_firmware
107 Siemens simatic_s7-1500_cpu_1511tf-1_firmware
108 Siemens simatic_s7-1500_cpu_1512c-1_firmware
109 Siemens simatic_s7-1500_cpu_1512sp-1_firmware
110 Siemens simatic_s7-1500_cpu_1512spf-1_firmware
111 Siemens simatic_s7-1500_cpu_1513-1_firmware
112 Siemens simatic_s7-1500_cpu_1513f-1_firmware
113 Siemens simatic_s7-1500_cpu_1513r-1_firmware
114 Siemens simatic_s7-1500_cpu_1515-2_firmware
115 Siemens simatic_s7-1500_cpu_151511c-1_firmware
116 Siemens simatic_s7-1500_cpu_151511f-1_firmware
117 Siemens simatic_s7-1500_cpu_1515f-2_firmware
118 Siemens simatic_s7-1500_cpu_1515r-2_firmware
119 Siemens simatic_s7-1500_cpu_1515t-2_firmware
120 Siemens simatic_s7-1500_cpu_1515tf-2_firmware
121 Siemens simatic_s7-1500_cpu_1516-3_firmware
122 Siemens simatic_s7-1500_cpu_1516-3_dp_firmware
123 Siemens simatic_s7-1500_cpu_1516-3_pn_firmware
124 Siemens simatic_s7-1500_cpu_1516f-3_firmware
125 Siemens simatic_s7-1500_cpu_1516pro-2_firmware
126 Siemens simatic_s7-1500_cpu_1516pro_f_firmware
127 Siemens simatic_s7-1500_cpu_1516t-3_firmware
128 Siemens simatic_s7-1500_cpu_1516tf-3_firmware
129 Siemens simatic_s7-1500_cpu_1517-3_firmware
130 Siemens simatic_s7-1500_cpu_1517-3_dp_firmware
131 Siemens simatic_s7-1500_cpu_1517-3_pn_firmware
132 Siemens simatic_s7-1500_cpu_1517f-3_firmware
133 Siemens simatic_s7-1500_cpu_1517tf-3_firmware
134 Siemens simatic_s7-1500_cpu_1518-4_firmware
135 Siemens simatic_s7-1500_cpu_1518-4_dp_firmware
136 Siemens simatic_s7-1500_cpu_1518-4_pn_firmware
137 Siemens simatic_s7-1500_cpu_1518f-4_firmware
138 Siemens simatic_s7-1500_cpu_1518hf-4_firmware
139 Siemens simatic_s7-1500_cpu_1518t-4_firmware
140 Siemens simatic_s7-1500_cpu_1518tf-4_firmware
141 Siemens simatic_s7-1500_cpu_15pro-2_firmware
142 Siemens simatic_s7-1500_cpu_15prof-2_firmware
143 Siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware
144 Siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware
145 Siemens siplus_s7-300_cpu_315-2_pn\/dp_firmware
146 Siemens siplus_s7-300_cpu_317-2_pn\/dp_firmware
147 Siemens simatic_s7-300_cpu_319-3_pn\/dp_firmware
148 Siemens simatic_s7-300_cpu_315-2_pn\/dp_firmware
149 Siemens simatic_s7-300_cpu_317-2_pn\/dp_firmware
150 Siemens sinumerik_one_firmware
151 Siemens 6es7154-8fb01-0ab0_firmware
152 Siemens 6es7154-8ab01-0ab0_firmware
153 Siemens 6es7154-8fx00-0ab0_firmware
154 Siemens 6es7151-8ab01-0ab0_firmware
155 Siemens 6es7151-8fb01-0ab0_firmware
156 Siemens 6es7314-6eh04-0ab0_firmware
157 Siemens 6es7315-2eh14-0ab0_firmware
158 Siemens 6es7315-2fj14-0ab0_firmware
159 Siemens 6es7315-7tj10-0ab0_firmware
160 Siemens 6es7317-2ek14-0ab0_firmware
161 Siemens 6es7317-2fk14-0ab0_firmware
162 Siemens 6es7317-7tk10-0ab0_firmware
163 Siemens 6es7317-7ul10-0ab0_firmware
164 Siemens 6es7318-3el01-0ab0_firmware
165 Siemens 6es7318-3fl01-0ab0_firmware
166 Siemens 6ag1151-8ab01-7ab0_firmware
167 Siemens 6ag1151-8fb01-2ab0_firmware
168 Siemens 6ag1314-6eh04-7ab0_firmware
169 Siemens 6ag1315-2eh14-7ab0_firmware
170 Siemens 6ag1315-2fj14-2ab0_firmware
171 Siemens 6ag1317-2ek14-7ab0_firmware
172 Siemens 6ag1317-2fk14-2ab0_firmware
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2022-30694.

URL Resource
https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf Patch Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2022-30694 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2022-30694 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • CVE Modified by [email protected]

    Apr. 11, 2023

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
  • CVE Modified by [email protected]

    Jan. 10, 2023

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
    Added CVSS V3.1 Siemens AG AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
  • CVE Modified by [email protected]

    Dec. 13, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
  • CVE Modified by [email protected]

    Dec. 13, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
  • Initial Analysis by [email protected]

    Nov. 09, 2022

    Action Type Old Value New Value
    Added CVSS V3.1 NIST AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N
    Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf Patch, Vendor Advisory
    Added CWE NIST CWE-352
    Added CPE Configuration OR *cpe:2.3:a:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:* *cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7154-8fb01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7154-8fb01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7154-8ab01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7154-8ab01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7154-8fx00-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7154-8fx00-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7151-8ab01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7151-8ab01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7151-8fb01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7151-8fb01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7314-6eh04-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.19 OR cpe:2.3:h:siemens:6es7314-6eh04-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7315-2eh14-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7315-2eh14-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7315-2fj14-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7315-2fj14-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7315-7tj10-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7315-7tj10-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7317-2ek14-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7317-2ek14-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7317-2fk14-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7317-2fk14-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7317-7tk10-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7317-7tk10-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7317-7ul10-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7317-7ul10-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7318-3el01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7318-3el01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6es7318-3fl01-0ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6es7318-3fl01-0ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1151-8ab01-7ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1151-8ab01-7ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1151-8fb01-2ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1151-8fb01-2ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1314-6eh04-7ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.19 OR cpe:2.3:h:siemens:6ag1314-6eh04-7ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1315-2eh14-7ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1315-2eh14-7ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1315-2fj14-2ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1315-2fj14-2ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1317-2ek14-7ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1317-2ek14-7ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:6ag1317-2fk14-2ab0_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.2.19 OR cpe:2.3:h:siemens:6ag1317-2fk14-2ab0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_pcs_firmware:*:*:*:*:*:*:*:* versions up to (including) 2.1 OR cpe:2.3:h:siemens:simatic_pcs:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_v7_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-400_pn\/dp_v7:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_v6_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-400_pn\/dp_v6:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_mfp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2022-30694 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2022-30694 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.08 }} -0.00%

score

0.34296

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability