Apache Geo SCADA Incorrect Authorization Denial of Service Vulnerability
Description
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
INFO
Published Date :
Jan. 31, 2023, 5:15 p.m.
Last Modified :
June 14, 2023, 8:15 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.2
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2023-22610
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2023-22610
.
URL | Resource |
---|---|
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf | Mitigation Patch Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2023-22610
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2023-22610
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Jun. 14, 2023
Action Type Old Value New Value Changed Description A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022) A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Removed CWE Schneider Electric SE CWE-285 Added CWE Schneider Electric SE CWE-863 Removed CWE Reason CWE-285 / Outside of 1003 -
Initial Analysis by [email protected]
Feb. 07, 2023
Action Type Old Value New Value Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Changed Reference Type https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf No Types Assigned https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf Mitigation, Patch, Vendor Advisory Added CWE NIST NVD-CWE-Other Added CPE Configuration OR *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:-:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7268.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7322.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7429.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7457.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7488.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7522.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7545.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7578.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7613.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7641.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7690.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7714.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7742.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7777.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7808.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7840.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7875.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7896.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7936.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7980.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8015.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8108.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8122.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8155.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8172.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8197.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8220.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8267.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:-:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7551.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7578.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7613.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7641.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7692.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7717.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7742.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7787.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7809.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7840.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7875.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7913.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7936.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7980.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8017.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8108.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8122.2:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8155.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8181.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8197.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8221.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8267.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:-:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8027.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8108.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8120.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8158.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8182.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8197.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8218.1:*:*:*:*:*:*:* *cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8269.1:*:*:*:*:*:*:* -
CVE Modified by [email protected]
Feb. 03, 2023
Action Type Old Value New Value Changed Description A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure™ Geo SCADA Expert 2019, EcoStruxure™ Geo SCADA Expert 2020, EcoStruxure™ Geo SCADA Expert 2021 (All versions prior to October 2022), ClearSCADA (All Versions). A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022) Removed Reference https://www.se.com/ww/en/download/document/SEVD-2023-010-02/ [No Types Assigned] Added Reference https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf [No Types Assigned] -
CVE Modified by [email protected]
Jan. 31, 2023
Action Type Old Value New Value Changed Description A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxureâ„¢ Geo SCADA Expert 2019, EcoStruxureâ„¢ Geo SCADA Expert 2020, EcoStruxureâ„¢ Geo SCADA Expert 2021 (All versions prior to October 2022), ClearSCADA (All Versions). A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure™ Geo SCADA Expert 2019, EcoStruxure™ Geo SCADA Expert 2020, EcoStruxure™ Geo SCADA Expert 2021 (All versions prior to October 2022), ClearSCADA (All Versions).
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2023-22610
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2023-22610
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.09 }} 0.00%
score
0.38975
percentile