CVE-2023-28831
OPC UA DoS - Integer Overflow in Certificate Validation
Description
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
INFO
Published Date :
Sept. 12, 2023, 10:15 a.m.
Last Modified :
June 17, 2026, 5:48 a.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2023-28831
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS | 134c704f-9b21-4f2e-91b3-4a467353bcc0 | |||||
| CVSS 3.1 | HIGH | [email protected] | ||||
| CVSS 3.1 | HIGH | [email protected] | ||||
| CVSS 4.0 | HIGH | [email protected] |
Public PoC/Exploit Available at Github
CVE-2023-28831 has a 1 public
PoC/Exploit available at Github.
Go to the Public Exploits tab to see the list.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2023-28831.
| URL | Resource |
|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-118850.html | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/html/ssa-711309.html | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf | Vendor Advisory |
| https://cert-portal.siemens.com/productcert/html/ssa-118850.html | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/html/ssa-711309.html | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf | Mitigation Vendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf | Vendor Advisory |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2023-28831 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2023-28831
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
None
Makefile Python HTML Jupyter Notebook
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2023-28831 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2023-28831 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Jun. 17, 2026
Action Type Old Value New Value Added SSVC {'id': 'CVE-2023-28831', 'role': 'CISA Coordinator', 'options': [{'exploitation': 'none'}, {'automatable': 'yes'}, {'technicalImpact': 'partial'}], 'version': '2.0.3', 'timestamp': '2025-06-25T13:40:30.354718Z'} -
CVE Modified by [email protected]
Jun. 17, 2026
Action Type Old Value New Value Added Affected [{'vendor': 'Siemens', 'product': 'SIMATIC BRAUMAT', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.1 SP1', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Cloud Connect 7 CC712', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Cloud Connect 7 CC716', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Comfort/Mobile RT', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Drive Controller CPU 1504D TF', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Drive Controller CPU 1504D TF', 'versions': [{'status': 'affected', 'version': 'V3.0.1', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Drive Controller CPU 1507D TF', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC Drive Controller CPU 1507D TF', 'versions': [{'status': 'affected', 'version': 'V3.0.1', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1510SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1510SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1510SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1510SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1512SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1512SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1512SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1512SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1514SP F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1514SP-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1514SPT F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP CPU 1514SPT-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V21.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)', 'versions': [{'status': 'affected', 'version': 'V30.0.0', 'lessThan': 'V30.1.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC IPC DiagMonitor', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC NET PC Software V14', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC NET PC Software V16', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V16 Update 8', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC NET PC Software V17', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V17 SP1 Update 1', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC NET PC Software V18', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V18 Update 1', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC PCS 7 V9.1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V9.1 SP2 UC08', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC PCS neo V4.0', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511C-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511C-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511T-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511T-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511TF-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1511TF-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1512C-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1512C-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1513F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515T-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515T-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515TF-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1515TF-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516T-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1516TF-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1517-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1517F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1517T-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1517TF-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518-4 PN/DP MFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518F-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518T-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU 1518TF-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 Software Controller V2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V21.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-1500 Software Controller V3', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V30.1.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC S7-PLCSIM Advanced', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.0 Update 2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC SISTAR', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.1 SP1', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC OA V3.17', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.17 P029', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC OA V3.18', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.18 P019', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC OA V3.19', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.19 P005', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC OPC UA Client', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.0.0.1', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC Runtime Professional V16', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC Runtime Professional V17', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC Runtime Professional V18', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC Runtime Professional V19', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V19 Update 2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC Unified OPC UA Server', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.0.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC V7.4', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC V7.5', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V7.5 SP2 Update 20', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIMATIC WinCC V8.0', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.0 Update 5', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SINUMERIK MC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.22', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SINUMERIK ONE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.22', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1510SP-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS ET 200SP CPU 1512SP-1 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN TX RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511-1 PN TX RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1511F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1513F-1 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1515F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1515F-2 PN', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1515F-2 PN RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516F-3 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.9.7', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1518-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1518-4 PN/DP MFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS S7-1500 CPU 1518F-4 PN/DP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}] -
CVE Modified by [email protected]
Aug. 18, 2025
Action Type Old Value New Value Added CVSS V4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X -
Modified Analysis by [email protected]
Apr. 10, 2025
Action Type Old Value New Value Added CVSS V3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Added CWE CWE-190 Added Reference Type Siemens AG: https://cert-portal.siemens.com/productcert/html/ssa-118850.html Types: Mitigation, Vendor Advisory Added Reference Type CVE: https://cert-portal.siemens.com/productcert/html/ssa-118850.html Types: Mitigation, Vendor Advisory Added Reference Type Siemens AG: https://cert-portal.siemens.com/productcert/html/ssa-711309.html Types: Mitigation, Vendor Advisory Added Reference Type CVE: https://cert-portal.siemens.com/productcert/html/ssa-711309.html Types: Mitigation, Vendor Advisory Added Reference Type Siemens AG: https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf Types: Mitigation, Vendor Advisory Added Reference Type CVE: https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf Types: Mitigation, Vendor Advisory -
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://cert-portal.siemens.com/productcert/html/ssa-118850.html Added Reference https://cert-portal.siemens.com/productcert/html/ssa-711309.html Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf -
CVE Modified by [email protected]
Jun. 11, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Feb. 13, 2024
Action Type Old Value New Value Added Reference Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-711309.html [No types assigned] Added Reference Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-118850.html [No types assigned] -
CVE Modified by [email protected]
Dec. 12, 2023
Action Type Old Value New Value Added Reference Siemens AG https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf [No types assigned] -
CVE Modified by [email protected]
Oct. 10, 2023
Action Type Old Value New Value Changed Description The ANSI C OPC UA SDK contains an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. -
Initial Analysis by [email protected]
Sep. 20, 2023
Action Type Old Value New Value Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf Vendor Advisory Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_cloud_connect_7_cc712_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.2 OR cpe:2.3:h:siemens:simatic_cloud_connect_7_cc712:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_cloud_connect_7_cc716_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.2 OR cpe:2.3:h:siemens:simatic_cloud_connect_7_cc716:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.2 OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp_f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 21.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 30.0.0 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp_f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514sp-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514sp_f-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514sp_f-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514spt-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1514spt_f-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1514spt_f-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517h-3_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517h-3_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517t-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517t-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 21.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_mfp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_mfp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_mfp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_s7-1518-4_pn\/dp_odk_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_s7-1518-4_pn\/dp_odk:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_s7-1518f-4_pn\/dp_odk_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_s7-1518f-4_pn\/dp_odk:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_et_200pro_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_et_200pro:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_software_controller:v2:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-1500_software_controller:v3:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp-1_pn_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp-1_pn_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1510sp_f-1_pn_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp-1_pn_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp-1_pn_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_et_200sp_cpu_1512sp_f-1_pn_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_t1_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn_t1_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511-1_pn_tx_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511-1_pn_tx_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515f-2_pn_t2_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515f-2_pn_t2_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515r-2_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1515r-2_pn_tx_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1515r-2_pn_tx_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp_tx_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516-3_pn\/dp_tx_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516f-3_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1516f-3_pn\/dp_rail_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.7 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1516f-3_pn\/dp_rail:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1517h-3_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1517h-3_pn:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518-4_pn\/dp_mfp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518f-4_pn\/dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518f-4_pn\/dp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:siplus_s7-1500_cpu_1518hf-4_pn_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.3 OR cpe:2.3:h:siemens:siplus_s7-1500_cpu_1518hf-4_pn:-:*:*:*:*:*:*:*