Triangle MicroWorks SCADA Data Gateway Unauthenticated Arbitrary File Write Vulnerability
Description
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
INFO
Published Date :
May 3, 2024, 3:15 a.m.
Last Modified :
Nov. 21, 2024, 8:15 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
3.6
Exploitability Score :
0.7
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2023-39461
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2023-39461
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2023-39461
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new Added Reference https://www.zerodayinitiative.com/advisories/ZDI-23-1029/ -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Received by [email protected]
May. 03, 2024
Action Type Old Value New Value Added Description Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535. Added Reference Zero Day Initiative https://www.zerodayinitiative.com/advisories/ZDI-23-1029/ [No types assigned] Added Reference Zero Day Initiative https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new [No types assigned] Added CWE Zero Day Initiative CWE-117 Added CVSS V3 Zero Day Initiative AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:N
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2023-39461
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2023-39461
weaknesses.