0.0
NA
CVE-2024-11166
Rockwell Collins TCAS II Transponder Ground Station Impersonation Vulnerability
Description

For TCAS II systems using transponders compliant with MOPS earlier than RTCA DO-181F, an attacker can impersonate a ground station and issue a Comm-A Identity Request. This action can set the Sensitivity Level Control (SLC) to the lowest setting and disable the Resolution Advisory (RA), leading to a denial-of-service condition.

INFO

Published Date :

Jan. 22, 2025, 7:15 p.m.

Last Modified :

Jan. 22, 2025, 7:15 p.m.

Remotely Exploitable :

No

Impact Score :

Exploitability Score :

Affected Products

The following products are affected by CVE-2024-11166 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2024-11166.

URL Resource
https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-01

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2024-11166 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2024-11166 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Jan. 22, 2025

    Action Type Old Value New Value
    Added Description For TCAS II systems using transponders compliant with MOPS earlier than RTCA DO-181F, an attacker can impersonate a ground station and issue a Comm-A Identity Request. This action can set the Sensitivity Level Control (SLC) to the lowest setting and disable the Resolution Advisory (RA), leading to a denial-of-service condition.
    Added CVSS V4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CWE CWE-15
    Added Reference https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-01
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
NONE - Vulnerability Scoring System