5.5
MEDIUM
CVE-2024-12654
FabulaTech USB over Network Null Pointer Dereference Vulnerability
Description

A vulnerability classified as problematic was found in FabulaTech USB over Network 6.0.6.1. Affected by this vulnerability is the function 0x220408 in the library ftusbbus2.sys of the component IOCT Handler. The manipulation leads to null pointer dereference. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

INFO

Published Date :

Dec. 16, 2024, 4:15 p.m.

Last Modified :

Dec. 18, 2024, 1:42 p.m.

Remotely Exploitable :

No

Impact Score :

3.6

Exploitability Score :

1.8
Affected Products

The following products are affected by CVE-2024-12654 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Fabulatech usb_over_network
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2024-12654.

URL Resource
https://shareforall.notion.site/FabulaTech-USB-over-Network-Client-ftusbbus2-0x220408-NPD-DOS-15160437bb1e803e9b3df784e61c6dcd Exploit Third Party Advisory
https://vuldb.com/?ctiid.288523 Permissions Required
https://vuldb.com/?id.288523 Third Party Advisory
https://vuldb.com/?submit.456028 Third Party Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2024-12654 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2024-12654 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • Initial Analysis by [email protected]

    Dec. 18, 2024

    Action Type Old Value New Value
    Added CVSS V3.1 NIST AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
    Added CWE NIST CWE-476
    Added CPE Configuration OR *cpe:2.3:a:fabulatech:usb_over_network:6.0.6.1:*:*:*:*:*:*:*
    Changed Reference Type https://shareforall.notion.site/FabulaTech-USB-over-Network-Client-ftusbbus2-0x220408-NPD-DOS-15160437bb1e803e9b3df784e61c6dcd No Types Assigned https://shareforall.notion.site/FabulaTech-USB-over-Network-Client-ftusbbus2-0x220408-NPD-DOS-15160437bb1e803e9b3df784e61c6dcd Exploit, Third Party Advisory
    Changed Reference Type https://vuldb.com/?ctiid.288523 No Types Assigned https://vuldb.com/?ctiid.288523 Permissions Required
    Changed Reference Type https://vuldb.com/?id.288523 No Types Assigned https://vuldb.com/?id.288523 Third Party Advisory
    Changed Reference Type https://vuldb.com/?submit.456028 No Types Assigned https://vuldb.com/?submit.456028 Third Party Advisory
  • New CVE Received by [email protected]

    Dec. 16, 2024

    Action Type Old Value New Value
    Added Description A vulnerability classified as problematic was found in FabulaTech USB over Network 6.0.6.1. Affected by this vulnerability is the function 0x220408 in the library ftusbbus2.sys of the component IOCT Handler. The manipulation leads to null pointer dereference. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    Added CVSS V4.0 AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CVSS V3.1 AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
    Added CVSS V2 (AV:L/AC:L/Au:S/C:N/I:N/A:C)
    Added CWE CWE-476
    Added CWE CWE-404
    Added Reference https://shareforall.notion.site/FabulaTech-USB-over-Network-Client-ftusbbus2-0x220408-NPD-DOS-15160437bb1e803e9b3df784e61c6dcd
    Added Reference https://vuldb.com/?ctiid.288523
    Added Reference https://vuldb.com/?id.288523
    Added Reference https://vuldb.com/?submit.456028
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2024-12654 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2024-12654 weaknesses.

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability