CVE-2024-2764
Tenda AC10U Heap-based Stack Buffer Overflow
Description
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
INFO
Published Date :
March 21, 2024, 9:15 p.m.
Last Modified :
May 17, 2024, 2:38 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.8
Public PoC/Exploit Available at Github
CVE-2024-2764 has a 2 public PoC/Exploit
available at Github.
Go to the Public Exploits
tab to see the list.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-2764
.
URL | Resource |
---|---|
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md | |
https://vuldb.com/?ctiid.257601 | |
https://vuldb.com/?id.257601 |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Ini adalah repository kumpulan CVE v.5
allcve cve cvelist newcve
None
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-2764
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2024-2764
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 17, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Apr. 11, 2024
Action Type Old Value New Value -
CVE Received by [email protected]
Mar. 21, 2024
Action Type Old Value New Value Added Description A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Added Reference VulDB https://vuldb.com/?id.257601 [No types assigned] Added Reference VulDB https://vuldb.com/?ctiid.257601 [No types assigned] Added Reference VulDB https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md [No types assigned] Added CWE VulDB CWE-121 Added CVSS V2 VulDB (AV:N/AC:L/Au:S/C:C/I:C/A:C) Added CVSS V3.1 VulDB AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-2764
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-2764
weaknesses.