CVE-2024-33180
Tenda AC18 Stack-Based Buffer Overflow Vulnerability
Description
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.
INFO
Published Date :
July 16, 2024, 4:15 p.m.
Last Modified :
Nov. 21, 2024, 9:16 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2024-33180
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-33180
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-33180
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2024-33180
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac -
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Aug. 01, 2024
Action Type Old Value New Value Added CWE CISA-ADP CWE-120 Added CVSS V3.1 CISA-ADP AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H -
Initial Analysis by [email protected]
Jul. 19, 2024
Action Type Old Value New Value Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac No Types Assigned https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac Exploit Added CWE NIST CWE-787 Added CPE Configuration AND OR *cpe:2.3:o:tendacn:ac18_firmware:15.03.3.10:*:*:*:*:*:*:* OR cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:* -
CVE Received by [email protected]
Jul. 16, 2024
Action Type Old Value New Value Added Description Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. Added Reference MITRE https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac [No types assigned]
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-33180
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-33180
weaknesses.