9.0
CRITICAL CVSS 3.1
CVE-2024-3596
RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.
Description

RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.

INFO

Published Date :

July 9, 2024, 12:15 p.m.

Last Modified :

Oct. 15, 2026, 1:18 a.m.

Remotely Exploit :

Yes !
Affected Products

The following products are affected by CVE-2024-3596 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens sinec_ins
2 Siemens ruggedcom_crossbow
3 Siemens ruggedcom_rox_mx5000_firmware
4 Siemens ruggedcom_rox_rx1400_firmware
5 Siemens ruggedcom_rox_rx1500_firmware
6 Siemens ruggedcom_rox_rx1501_firmware
7 Siemens ruggedcom_rox_rx1510_firmware
8 Siemens ruggedcom_rox_rx1511_firmware
9 Siemens ruggedcom_rox_rx1512_firmware
10 Siemens ruggedcom_rox_rx1524_firmware
11 Siemens ruggedcom_rox_rx1536_firmware
12 Siemens ruggedcom_rox_rx5000_firmware
13 Siemens ruggedcom_rox_mx5000re_firmware
14 Siemens ruggedcom_ape1808_firmware
15 Siemens scalance_x308-2m
16 Siemens scalance_m804pb
17 Siemens scalance_m874-2
18 Siemens scalance_m874-3
19 Siemens scalance_m876-3
20 Siemens scalance_m876-4
21 Siemens scalance_mum856-1
22 Siemens scalance_sc622-2c
23 Siemens scalance_sc626-2c
24 Siemens scalance_sc632-2c
25 Siemens scalance_sc636-2c
26 Siemens scalance_sc642-2c
27 Siemens scalance_sc646-2c
28 Siemens siprotec_5_6md85
29 Siemens siprotec_5_6md86
30 Siemens siprotec_5_6md89
31 Siemens siprotec_5_6mu85
32 Siemens siprotec_5_7ke85
33 Siemens siprotec_5_7sa82
34 Siemens siprotec_5_7sa86
35 Siemens siprotec_5_7sa87
36 Siemens siprotec_5_7sd82
37 Siemens siprotec_5_7sd86
38 Siemens siprotec_5_7sd87
39 Siemens siprotec_5_7sj81
40 Siemens siprotec_5_7sj82
41 Siemens siprotec_5_7sj85
42 Siemens siprotec_5_7sj86
43 Siemens siprotec_5_7sk82
44 Siemens siprotec_5_7sk85
45 Siemens siprotec_5_7sl82
46 Siemens siprotec_5_7sl86
47 Siemens siprotec_5_7sl87
48 Siemens siprotec_5_7ss85
49 Siemens siprotec_5_7st85
50 Siemens siprotec_5_7sx85
51 Siemens siprotec_5_7um85
52 Siemens siprotec_5_7ut82
53 Siemens siprotec_5_7ut85
54 Siemens siprotec_5_7ut86
55 Siemens siprotec_5_7ut87
56 Siemens siprotec_5_7ve85
57 Siemens siprotec_5_7vk87
58 Siemens siprotec_5_compact_7sx800
59 Siemens siprotec_5_7st86
60 Siemens siprotec_5_7sx82
61 Siemens siprotec_5_7vu85
62 Siemens scalance_x304-2fe
63 Siemens scalance_x307-3
64 Siemens scalance_x307-3ld
65 Siemens scalance_x308-2
66 Siemens scalance_x308-2ld
67 Siemens scalance_x308-2lh
68 Siemens scalance_x308-2m_poe
69 Siemens scalance_x308-2m_ts
70 Siemens scalance_x310
71 Siemens scalance_x310fe
72 Siemens scalance_xf204
73 Siemens scalance_xr324-4m_eec
74 Siemens scalance_xr324-4m_poe
75 Siemens scalance_xr324-4m_poe_ts
76 Siemens scalance_xr324-12m
77 Siemens scalance_xr324-12m_ts
78 Siemens scalance_xc206-2g_poe
79 Siemens scalance_xc206-2sfp
80 Siemens scalance_xc206-2sfp_eec
81 Siemens scalance_xc206-2sfp_g
82 Siemens scalance_xc206-2sfp_g_eec
83 Siemens scalance_xc208
84 Siemens scalance_xc208eec
85 Siemens scalance_xc208g
86 Siemens scalance_xc208g_eec
87 Siemens scalance_xc208g_poe
88 Siemens scalance_xc216
89 Siemens scalance_xc216-3g_poe
90 Siemens scalance_xc216-4c
91 Siemens scalance_xc216-4c_g
92 Siemens scalance_xc216-4c_g_eec
93 Siemens scalance_xc216eec
94 Siemens scalance_xc224
95 Siemens scalance_xc224-4c_g
96 Siemens scalance_xc224-4c_g_eec
97 Siemens scalance_xf204_dna
98 Siemens scalance_xf204-2ba
99 Siemens scalance_xf204-2ba_dna
100 Siemens scalance_xp208
101 Siemens scalance_xp208eec
102 Siemens scalance_xp208poe_eec
103 Siemens scalance_xp216
104 Siemens scalance_xp216eec
105 Siemens scalance_xp216poe_eec
106 Siemens scalance_xr326-2c_poe_wg
107 Siemens siplus_net_scalance_xc206-2
108 Siemens siplus_net_scalance_xc206-2sfp
109 Siemens siplus_net_scalance_xc208
110 Siemens siplus_net_scalance_xc216-4c
111 Siemens scalance_xr528-6m
112 Siemens scalance_m812-1_adsl-router
113 Siemens scalance_m816-1_adsl-router
114 Siemens scalance_m826-2_shdsl-router
115 Siemens scalance_mum853-1
116 Siemens scalance_w721-1_rj45
117 Siemens scalance_w722-1_rj45
118 Siemens scalance_w734-1_rj45
119 Siemens scalance_w738-1_m12
120 Siemens scalance_w748-1_m12
121 Siemens scalance_w761-1_rj45
122 Siemens scalance_w774-1_m12_eec
123 Siemens scalance_w774-1_rj45
124 Siemens scalance_w778-1_m12
125 Siemens scalance_w778-1_m12_eec
126 Siemens scalance_w786-1_rj45
127 Siemens scalance_w786-2_rj45
128 Siemens scalance_w786-2_sfp
129 Siemens scalance_w786-2ia_rj45
130 Siemens scalance_w788-1_m12
131 Siemens scalance_w788-1_rj45
132 Siemens scalance_w788-2_m12
133 Siemens scalance_w788-2_m12_eec
134 Siemens scalance_w1748-1_m12
135 Siemens scalance_w1788-1_m12
136 Siemens scalance_w1788-2_eec_m12
137 Siemens scalance_w1788-2_m12
138 Siemens scalance_w1788-2ia_m12
139 Siemens scalance_wam763-1
140 Siemens scalance_wam766-1
141 Siemens scalance_wum763-1
142 Siemens scalance_wum766-1
143 Siemens scalance_xb205-3
144 Siemens scalance_xb205-3ld
145 Siemens scalance_xb208
146 Siemens scalance_xb213-3
147 Siemens scalance_xb213-3ld
148 Siemens scalance_xb216
149 Siemens scalance_xc206-2
150 Siemens scalance_xc206-2g_poe_eec
151 Siemens scalance_xm408-4c
152 Siemens scalance_xm408-8c
153 Siemens scalance_xm416-4c
154 Siemens scalance_xr324wg
155 Siemens scalance_xr328-4c_wg
156 Siemens scalance_xr552-12m
157 Siemens scalance_s615_eec_lan-router
158 Siemens scalance_s615_lan-router
159 Siemens ruggedcom_rsg2488
160 Siemens ruggedcom_rsl910
161 Siemens ruggedcom_rox_mx5000
162 Siemens ruggedcom_rox_rx1400
163 Siemens ruggedcom_rox_rx1500
164 Siemens ruggedcom_rox_rx1501
165 Siemens ruggedcom_rox_rx1510
166 Siemens ruggedcom_rox_rx1511
167 Siemens ruggedcom_rox_rx1512
168 Siemens ruggedcom_rox_rx5000
169 Siemens scalance_x408-2
170 Siemens ruggedcom_rox_rx1524
171 Siemens ruggedcom_rox_rx1536
172 Siemens ruggedcom_i800
173 Siemens ruggedcom_i801
174 Siemens ruggedcom_i802
175 Siemens ruggedcom_i803
176 Siemens ruggedcom_m969
177 Siemens ruggedcom_m2100
178 Siemens ruggedcom_m2200
179 Siemens ruggedcom_rmc30
180 Siemens ruggedcom_rmc8388
181 Siemens ruggedcom_rp110
182 Siemens ruggedcom_rs400
183 Siemens ruggedcom_rs401
184 Siemens ruggedcom_rs416
185 Siemens ruggedcom_rs416v2
186 Siemens ruggedcom_rs900
187 Siemens ruggedcom_rs900g
188 Siemens ruggedcom_rs900gp
189 Siemens ruggedcom_rs900l
190 Siemens ruggedcom_rs900w
191 Siemens ruggedcom_rs910
192 Siemens ruggedcom_rs910l
193 Siemens ruggedcom_rs910w
194 Siemens ruggedcom_rs920l
195 Siemens ruggedcom_rs920w
196 Siemens ruggedcom_rs930l
197 Siemens ruggedcom_rs930w
198 Siemens ruggedcom_rs940g
199 Siemens ruggedcom_rs969
200 Siemens ruggedcom_rs8000
201 Siemens ruggedcom_rs8000a
202 Siemens ruggedcom_rs8000h
203 Siemens ruggedcom_rs8000t
204 Siemens ruggedcom_rsg920p
205 Siemens ruggedcom_rsg2100
206 Siemens ruggedcom_rsg2100p
207 Siemens ruggedcom_rsg2200
208 Siemens ruggedcom_rsg2288
209 Siemens ruggedcom_rsg2300
210 Siemens ruggedcom_rsg2300p
211 Siemens ruggedcom_rst916c
212 Siemens ruggedcom_rst916p
213 Siemens ruggedcom_rst2228
214 Siemens ruggedcom_ape1808
215 Siemens ruggedcom_rsg907r
216 Siemens ruggedcom_rsg908c
217 Siemens ruggedcom_rsg909r
218 Siemens ruggedcom_rsg910c
219 Siemens ruggedcom_rst2228p
220 Siemens siplus_net_scalance_x308-2
221 Siemens ruggedcom_rox_mx5000re
222 Siemens ruggedcom_rs416pv2
223 Siemens ruggedcom_i800nc
224 Siemens ruggedcom_i801nc
225 Siemens ruggedcom_i802nc
226 Siemens ruggedcom_i803nc
227 Siemens ruggedcom_m2100nc
228 Siemens ruggedcom_m2200nc
229 Siemens ruggedcom_m969nc
230 Siemens ruggedcom_rmc30nc
231 Siemens ruggedcom_rp110nc
232 Siemens ruggedcom_rs1600
233 Siemens ruggedcom_rs1600f
234 Siemens ruggedcom_rs1600fnc
235 Siemens ruggedcom_rs1600nc
236 Siemens ruggedcom_rs1600t
237 Siemens ruggedcom_rs1600tnc
238 Siemens ruggedcom_rs400nc
239 Siemens ruggedcom_rs401nc
240 Siemens ruggedcom_rs416nc
241 Siemens ruggedcom_rs416p
242 Siemens ruggedcom_rs416pnc
243 Siemens ruggedcom_rs8000anc
244 Siemens ruggedcom_rs8000hnc
245 Siemens ruggedcom_rs8000nc
246 Siemens ruggedcom_rs8000tnc
247 Siemens ruggedcom_rs900gnc
248 Siemens ruggedcom_rs900gpnc
249 Siemens ruggedcom_rs900lnc
250 Siemens ruggedcom_rs900m-gets-c01
251 Siemens ruggedcom_rs900m-gets-xx
252 Siemens ruggedcom_rs900m-stnd-c01
253 Siemens ruggedcom_rs900m-stnd-xx
254 Siemens ruggedcom_rs900mnc-gets-c01
255 Siemens ruggedcom_rs900mnc-gets-xx
256 Siemens ruggedcom_rs900mnc-stnd-xx
257 Siemens ruggedcom_rs900mnc-stnd-xx-c01
258 Siemens ruggedcom_rs900nc
259 Siemens ruggedcom_rs910lnc
260 Siemens ruggedcom_rs910nc
261 Siemens ruggedcom_rs920lnc
262 Siemens ruggedcom_rs930lnc
263 Siemens ruggedcom_rs940gnc
264 Siemens ruggedcom_rs969nc
265 Siemens ruggedcom_rsg2100nc
266 Siemens ruggedcom_rsg2100pnc
267 Siemens ruggedcom_rsg2200nc
268 Siemens ruggedcom_rmc8388nc
269 Siemens ruggedcom_rsg2288nc
270 Siemens ruggedcom_rsg2300nc
271 Siemens ruggedcom_rsg2300pnc
272 Siemens ruggedcom_rsg2488nc
273 Siemens ruggedcom_rsg920pnc
274 Siemens ruggedcom_rsl910nc
275 Siemens ruggedcom_rst2428p
276 Siemens scalance_xc316-8
277 Siemens scalance_xc324-4
278 Siemens scalance_xc332
279 Siemens scalance_xc416-8
280 Siemens scalance_xc424-4
281 Siemens scalance_xc432
282 Siemens scalance_xch328
283 Siemens scalance_xcm324
284 Siemens scalance_xcm328
285 Siemens scalance_xcm332
286 Siemens scalance_xr302-32
287 Siemens scalance_xr322-12
288 Siemens scalance_xr326-8
289 Siemens scalance_xr502-32
290 Siemens scalance_xr522-12
291 Siemens scalance_xr524-8wg
292 Siemens scalance_xr526-8
293 Siemens scalance_xrh334
294 Siemens scalance_xrm334
295 Siemens scalance_wab762-1
296 Siemens scalance_wub762-1
297 Siemens scalance_wub762-1_ifeatures
298 Siemens scalance_m826-2_shdsl-router
299 Siemens sicore_base_system
1 Microsoft windows_server_2012
2 Microsoft windows_server_2016
3 Microsoft windows_server_2019
4 Microsoft windows_10_1607
5 Microsoft windows_10_1809
6 Microsoft windows_10_21h2
7 Microsoft windows_10_22h2
8 Microsoft windows_server_2022
9 Microsoft windows_11_21h2
10 Microsoft windows_11_22h2
11 Microsoft windows_10_1507
12 Microsoft windows_11_23h2
13 Microsoft windows_server_23h2
14 Microsoft windows_server_2012_r2
15 Microsoft windows_server_2008_r2
16 Microsoft windows_server_2008_sp2
1 Broadcom fabric_operating_system
2 Broadcom brocade_sannav
1 Sonicwall sonicos
1 Freeradius freeradius
1 Ietf rfc
CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 134c704f-9b21-4f2e-91b3-4a467353bcc0
CVSS 3.1 CRITICAL [email protected]
CVSS 3.1 CRITICAL 134c704f-9b21-4f2e-91b3-4a467353bcc0
Solution
Multiple vendors and software require updates to address RADIUS MD5 forgery vulnerabilities.
  • Update affected software packages to address the vulnerability.
  • Consult vendor advisories for specific patching instructions.
Public PoC/Exploit Available at Github

CVE-2024-3596 has a 13 public PoC/Exploit available at Github. Go to the Public Exploits tab to see the list.

References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2024-3596.

URL Resource
http://www.openwall.com/lists/oss-security/2024/07/09/4 Mailing List
https://cert-portal.siemens.com/productcert/html/ssa-723487.html
https://cert-portal.siemens.com/productcert/html/ssa-794185.html
https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Technical Description
https://datatracker.ietf.org/doc/html/rfc2865 Technical Description
https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Third Party Advisory
https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Third Party Advisory
https://www.blastradius.fail/ Technical Description
http://www.openwall.com/lists/oss-security/2024/07/09/4 Mailing List
https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Technical Description
https://datatracker.ietf.org/doc/html/rfc2865 Technical Description
https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Third Party Advisory
https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Third Party Advisory
https://security.netapp.com/advisory/ntap-20240822-0001/ Third Party Advisory
https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol Third Party Advisory
https://www.blastradius.fail/ Technical Description
https://www.kb.cert.org/vuls/id/456537
https://cert-portal.siemens.com/productcert/html/ssa-364175.html
https://cert-portal.siemens.com/productcert/html/ssa-723487.html
https://cert-portal.siemens.com/productcert/html/ssa-770770.html
https://cert-portal.siemens.com/productcert/html/ssa-794185.html
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2024-3596 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2024-3596 weaknesses.

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Test RADIUS servers (FreeRADIUS, Windows NPS, cloud) from inside your network — PEAP-MSCHAPv2, EAP-TLS, RadSec, path-MTU, BlastRADIUS posture, VLAN assertions. Plain-English 802.1X diagnostics.

802-1x cli diagnostics eap-tls freeradius golang msp network-monitoring networking nps peap radius radsec sysadmin

Go Shell

Updated: 4 months, 1 week ago
0 stars 0 fork 0 watcher
Born at : July 11, 2026, 6:06 p.m. This repo has been linked 1 different CVEs too.

None

Dockerfile JavaScript Astro TypeScript CSS Shell PHP Smarty HTML

Updated: 4 months, 2 weeks ago
0 stars 0 fork 0 watcher
Born at : July 8, 2026, 7:51 a.m. This repo has been linked 1 different CVEs too.

Ecash for SSH — pay-per-minute shell access with Cashu tokens

Makefile Go Shell JavaScript Python HTML Dockerfile TypeScript Nix

Updated: 4 months, 1 week ago
0 stars 0 fork 0 watcher
Born at : June 9, 2026, 8:17 p.m. This repo has been linked 1 different CVEs too.

Operator-focused, detail-oriented enumeration script kit for enumerating large networks.

Makefile Shell Python C PowerShell Batchfile

Updated: 4 months ago
0 stars 0 fork 0 watcher
Born at : May 23, 2026, 3:50 p.m. This repo has been linked 15 different CVEs too.

None

Updated: 6 months, 2 weeks ago
0 stars 0 fork 0 watcher
Born at : May 10, 2026, 5:25 p.m. This repo has been linked 1 different CVEs too.

An Open Source NAC Solution

Python HTML CSS Mako Dockerfile Shell

Updated: 4 months, 3 weeks ago
0 stars 0 fork 0 watcher
Born at : April 2, 2026, 4:22 p.m. This repo has been linked 1 different CVEs too.

PacketFence MAB Device Spoofing via Calling-Station-Id Tampering in RADIUS Access-Request

Dockerfile Python

Updated: 7 months, 3 weeks ago
0 stars 0 fork 0 watcher
Born at : March 31, 2026, 10:15 a.m. This repo has been linked 1 different CVEs too.

PacketFence VLAN Escalation via NAS-Port-Type Tampering in RADIUS Access-Request

Dockerfile Python

Updated: 7 months, 3 weeks ago
0 stars 0 fork 0 watcher
Born at : March 31, 2026, 8:32 a.m. This repo has been linked 1 different CVEs too.

RADIUS/FreeRADIUS Security Analysis & End-to-End PoC — 12 attack cases targeting RFC 2865 attribute handling

Python

Updated: 7 months, 3 weeks ago
0 stars 0 fork 0 watcher
Born at : March 30, 2026, 1:09 p.m. This repo has been linked 1 different CVEs too.

A python based passive and active firewall configuration and rule checker

firewall-configuration firewall-management firewall-rules ngfw-configuration fortigate-automation fortigate-configuration fortigate-firewall fortigate-firewall-configuration

Python HTML

Updated: 4 months, 2 weeks ago
1 stars 0 fork 0 watcher
Born at : March 14, 2026, 6:13 p.m. This repo has been linked 25 different CVEs too.

RADIUS protocol library for TypeScript/Node.js with packet parsing, construction, UDP server/client, FreeRADIUS dictionary support, vendor-specific attributes, and password encryption

aaa access-control accounting authentication freeradius nodejs radius radius-client radius-packet radius-protocol radius-server rfc2865 rfc2866 rfc2869 typescript udp vsa message-authenticator rfc2868 vendor-specific-attributes

JavaScript TypeScript

Updated: 5 months, 2 weeks ago
0 stars 0 fork 0 watcher
Born at : Feb. 9, 2026, 1:50 a.m. This repo has been linked 1 different CVEs too.

None

Updated: 1 year, 8 months ago
0 stars 0 fork 0 watcher
Born at : March 12, 2025, 3:57 p.m. This repo has been linked 126 different CVEs too.

None

Python

Updated: 2 years ago
7 stars 2 fork 2 watcher
Born at : July 9, 2024, 7:44 p.m. This repo has been linked 1 different CVEs too.

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2024-3596 vulnerability anywhere in the article.

  • Daily CyberSecurity
Windows User Count Controversy: Microsoft Silently “Corrects” User Base to 1.4 Billion After Implied 400M Drop

Hardware indicator for volume shown at the top center Last week, a Microsoft executive noted in a newly published blog post that Windows is currently in use on over one billion devices worldwide. This ... Read more

Published Date: Jul 02, 2025 (1 year, 4 months ago)
  • Cyber Security News
VMware Patches Multiple 47 Vulnerabilities VMware Tanzu Greenplum Backup & Components

VMware has released critical security updates to address 47 vulnerabilities across multiple VMware Tanzu Greenplum products, including 29 issues in VMware Tanzu Greenplum Backup and Restore and 18 bug ... Read more

Published Date: Apr 09, 2025 (1 year, 7 months ago)
  • Cyber Security News
Pegasus Spyware Used Widely to Target Individuals in Private Industry & Finance Sectors

Pegasus spyware, once considered a tool for targeting journalists and activists—is now being deployed against executives in the private sector, including finance, real estate, and logistics. In a Dece ... Read more

Published Date: Feb 21, 2025 (1 year, 9 months ago)
  • tripwire.com
Tripwire Patch Priority Index for July 2024

Tripwire's July 2024 Patch Priority Index (PPI) brings together important vulnerabilities for Microsoft.First on the list are patches for Microsoft Office and Outlook that resolve remote code executio ... Read more

Published Date: Aug 06, 2024 (2 years, 3 months ago)
  • europa.eu
Cyber Security Brief 24-08 - July 2024

Cyber Brief (July 2024)August 1, 2024 - Version: 1.0TLP:CLEARExecutive summaryWe analysed 252 open source reports for this Cyber Security Brief1.Cyber policy and law enforcement efforts in Europe have ... Read more

Published Date: Aug 01, 2024 (2 years, 3 months ago)
  • Cyber Security News
RADIUS Protocol Vulnerability Impacted Multiple Cisco Products

A critical vulnerability in the Remote Authentication Dial-In User Service (RADIUS) protocol has been disclosed, affecting multiple Cisco products. The vulnerability, CVE-2024-3596, allows an on-path ... Read more

Published Date: Jul 29, 2024 (2 years, 3 months ago)
  • The Cloudflare Blog
RADIUS/UDP vulnerable to improved MD5 collision attack

2024-07-0917 min readThe MD5 cryptographic hash function was first broken in 2004, when researchers demonstrated the first MD5 collision, namely two different messages X1 and X2 where MD5(X1) = MD5 (X ... Read more

Published Date: Jul 09, 2024 (2 years, 4 months ago)

The following table lists the changes that have been made to the CVE-2024-3596 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e

    Oct. 15, 2026

    Action Type Old Value New Value
    Added Affected Affected value modified. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2024/3xxx/CVE-2024-3596.json">CVE-2024-3596</a>
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-364175.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-770770.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-364175.html
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-770770.html
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Oct. 15, 2026

    Action Type Old Value New Value
    Added Reference http://www.openwall.com/lists/oss-security/2024/07/09/4
    Added Reference https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/
    Added Reference https://datatracker.ietf.org/doc/html/rfc2865
    Added Reference https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf
    Added Reference https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014
    Added Reference https://security.netapp.com/advisory/ntap-20240822-0001/
    Added Reference https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol
    Added Reference https://www.blastradius.fail/
    Added Reference https://www.kb.cert.org/vuls/id/456537
    Removed Reference http://www.openwall.com/lists/oss-security/2024/07/09/4
    Removed Reference https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/
    Removed Reference https://datatracker.ietf.org/doc/html/rfc2865
    Removed Reference https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf
    Removed Reference https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014
    Removed Reference https://security.netapp.com/advisory/ntap-20240822-0001/
    Removed Reference https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol
    Removed Reference https://www.blastradius.fail/
    Removed Reference https://www.kb.cert.org/vuls/id/456537
    Removed Reference Type http://www.openwall.com/lists/oss-security/2024/07/09/4 Types: Mailing List
    Removed Reference Type https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Types: Technical Description
    Removed Reference Type https://datatracker.ietf.org/doc/html/rfc2865 Types: Technical Description
    Removed Reference Type https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Types: Third Party Advisory
    Removed Reference Type https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Types: Third Party Advisory
    Removed Reference Type https://security.netapp.com/advisory/ntap-20240822-0001/ Types: Third Party Advisory
    Removed Reference Type https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol Types: Third Party Advisory
    Removed Reference Type https://www.blastradius.fail/ Types: Technical Description
  • CVE Modified by [email protected]

    Oct. 15, 2026

    Action Type Old Value New Value
    Added Reference http://www.openwall.com/lists/oss-security/2024/07/09/4
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
    Added Reference https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/
    Added Reference https://datatracker.ietf.org/doc/html/rfc2865
    Added Reference https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf
    Added Reference https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014
    Added Reference https://www.blastradius.fail/
    Removed Reference http://www.openwall.com/lists/oss-security/2024/07/09/4
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Removed Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
    Removed Reference https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/
    Removed Reference https://datatracker.ietf.org/doc/html/rfc2865
    Removed Reference https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf
    Removed Reference https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014
    Removed Reference https://www.blastradius.fail/
    Removed Reference Type http://www.openwall.com/lists/oss-security/2024/07/09/4 Types: Mailing List
    Removed Reference Type https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Types: Technical Description
    Removed Reference Type https://datatracker.ietf.org/doc/html/rfc2865 Types: Technical Description
    Removed Reference Type https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Types: Third Party Advisory
    Removed Reference Type https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Types: Third Party Advisory
    Removed Reference Type https://www.blastradius.fail/ Types: Technical Description
  • CVE Modified by [email protected]

    Jun. 17, 2026

    Action Type Old Value New Value
    Added Affected [{'vendor': 'IETF', 'product': 'RFC', 'versions': [{'status': 'affected', 'version': '2865'}]}]
  • CVE Modified by 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e

    Jun. 17, 2026

    Action Type Old Value New Value
    Added Affected [{'vendor': 'Siemens', 'product': 'CPC80 Central Processing/Communication', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V16.51', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'CPCI85 Central Processing/Communication', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.20', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'POWER METER SICAM Q100 family', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.70', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'POWER METER SICAM Q200 family', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.83', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'Powerlink IP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.22', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM APE1808', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM APE1808', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM CROSSBOW', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i800', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i800NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i801', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i801NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i802', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i802NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i803', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM i803NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M2100', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M2100NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M2200', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M2200NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M969', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM M969NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RM1224 LTE(4G) EU', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RM1224 LTE(4G) NAM', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC30', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC30NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC8388 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC8388 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC8388NC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RMC8388NC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX MX5000', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX MX5000RE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1400', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1500', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1501', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1510', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1511', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1512', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1524', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX1536', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM ROX RX5000', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.17.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RP110', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RP110NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600F', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600FNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600T', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS1600TNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS400', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS400NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS401', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS401NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416NCv2 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416NCv2 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416P', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416PNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416PNCv2 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416PNCv2 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416Pv2 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416Pv2 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416v2 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS416v2 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000A', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000ANC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000H', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000HNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000T', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS8000TNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900 (32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900 (32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900G (32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900G (32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900GNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900GNC(32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900GNC(32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900GP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900GPNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900L', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900LNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900M-GETS-C01', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900M-GETS-XX', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900M-STND-C01', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900M-STND-XX', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900MNC-GETS-C01', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900MNC-GETS-XX', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900MNC-STND-XX', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900MNC-STND-XX-C01', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900NC(32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900NC(32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS900W', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS910', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS910L', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS910LNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS910NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS910W', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS920L', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS920LNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS920W', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS930L', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS930LNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS930W', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS940G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS940GNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS969', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RS969NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100 (32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100 (32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100NC(32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100NC(32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100P', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100P (32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100P (32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100PNC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100PNC (32M) V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2100PNC (32M) V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2200', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2200NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2288 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2288 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2288NC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2288NC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300NC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300NC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300P V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300P V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300PNC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2300PNC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2488 V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2488 V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2488NC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG2488NC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG907R', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG908C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG909R', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG910C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG920P V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG920P V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG920PNC V4.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.3.11', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSG920PNC V5.X', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSL910', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RSL910NC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RST2228', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RST2228P', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RST2428P', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RST916C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'RUGGEDCOM RST916P', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V5.10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M804PB', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M812-1 ADSL-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M812-1 ADSL-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M816-1 ADSL-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M816-1 ADSL-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M826-2 SHDSL-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M874-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M874-3', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M874-3 3G-Router (CN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M876-3', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M876-3 (ROK)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M876-4', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M876-4 (EU)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE M876-4 (NAM)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM853-1 (A1)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM853-1 (B1)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM853-1 (EU)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM856-1 (A1)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM856-1 (B1)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM856-1 (CN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM856-1 (EU)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE MUM856-1 (RoW)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE S615 EEC LAN-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE S615 LAN-Router', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V8.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC622-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC626-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC632-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC636-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC642-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE SC646-2C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1748-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1748-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1788-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1788-2 EEC M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1788-2 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W1788-2IA M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W721-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W721-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W722-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W722-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W722-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W734-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W734-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W734-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W734-1 RJ45 (USA)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W738-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W738-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W748-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W748-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W748-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W748-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W761-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W761-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W774-1 RJ45 (USA)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W778-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W778-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W778-1 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W778-1 M12 EEC (USA)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2 SFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2 SFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2IA RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W786-2IA RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-1 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-1 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 M12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 M12 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE W788-2 RJ45', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V6.6.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAB762-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM763-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM763-1 (ME)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM763-1 (US)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1 (ME)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1 (US)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1 EEC (ME)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WAM766-1 EEC (US)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUB762-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUB762-1 iFeatures', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM763-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM763-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM763-1 (US)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM763-1 (US)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM766-1', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM766-1 (ME)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE WUM766-1 (USA)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.0.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (230V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (24V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (2x 230V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (2x 230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (2x 24V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X302-7 EEC (2x 24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X304-2FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X306-1LD FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (230V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (24V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (2x 230V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (2x 230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (2x 24V, coated)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-2 EEC (2x 24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-3', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-3', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-3LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X307-3LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LH', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LH', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LH+', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2LH+', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M PoE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M PoE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M TS', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X308-2M TS', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X310', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X310', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X310FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X310FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X320-1 FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X320-1-2LD FE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE X408-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3 (SC, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3 (ST, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3 (ST, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3 (ST, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3LD (SC, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB205-3LD (SC, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2 (SC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2 (ST/BFOC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2 LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2 SC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2 ST', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB206-2LD', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB208 (E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB208 (PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3 (SC, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3 (SC, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3 (ST, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3 (ST, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3LD (SC, E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB213-3LD (SC, PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB216 (E/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XB216 (PN)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2 (SC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2 (ST/BFOC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2G PoE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2G PoE (54 V DC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2G PoE EEC (54 V DC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2SFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2SFP EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2SFP G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2SFP G (EIP DEF.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC206-2SFP G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208G (EIP def.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208G PoE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC208G PoE (54 V DC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-3G PoE', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-3G PoE (54 V DC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-4C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-4C G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-4C G (EIP Def.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216-4C G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC216EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC224', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC224-4C G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC224-4C G (EIP Def.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC224-4C G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC316-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC324-4', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC324-4 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC332', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC416-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC424-4', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XC432', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XCH328', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XCM324', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XCM328', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XCM332', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XF204', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XF204 DNA', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XF204-2BA', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XF204-2BA DNA', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XF204G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM408-4C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM408-4C (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM408-8C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM408-8C (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM416-4C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XM416-4C (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208 (Ethernet/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208G PoE EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208G PP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208PoE EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP208PoE EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216 (Ethernet/IP)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216 (V2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216EEC (V2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216G', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216G EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216G PoE EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216POE EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XP216PoE EEC (V2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR302-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR302-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR302-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR322-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR322-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR322-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (230V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (230V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (230V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (230V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M TS (24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-12M TS (24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M EEC (2x 24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (230V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (230V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (230V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (230V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE (24V, ports on rear)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE TS (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324-4M PoE TS (24V, ports on front)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324WG (24 x FE, AC 230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR324WG (24 X FE, DC 24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-2C PoE WG', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-2C PoE WG (without UL)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR326-8 EEC', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (28xGE, AC 230V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR328-4C WG (28xGE, DC 24V)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR502-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR502-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR502-32', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR522-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR522-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR522-12', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 1x230V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 1x230V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 24V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 24V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 2x230V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8C, 2x230V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8WG', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8WG', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8WG', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR524-8WG', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.3', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 1x230V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 1x230V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 24V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 24V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 2x230V', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR526-8C, 2x230V (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR528-6M', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR528-6M (2HR2, L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR528-6M (2HR2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR528-6M (L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR552-12M', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR552-12M (2HR2, L3 int.)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR552-12M (2HR2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XR552-12M (2HR2)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRH334 (24 V DC, 8xFO, CC)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (230 V AC, 12xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (230 V AC, 8xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (24 V DC, 12xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (24 V DC, 8xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (2x230 V AC, 12xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (2x230 V AC, 8xFO)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V3.2', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM AK 3', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM BC', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM GridEdge (Classic)', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM GridEdge Applications for SICAM 8 Platform', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM GridPass', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.50', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICAM TM', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SICORE Base system', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V2.20.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SINEC INS', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V1.0 SP2 Update 4', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS NET SCALANCE X308-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.1.9', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS NET SCALANCE XC206-2', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS NET SCALANCE XC206-2SFP', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS NET SCALANCE XC208', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPLUS NET SCALANCE XC216-4C', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V4.6', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 - CP200 Devices', 'versions': [{'status': 'unaffected', 'version': '0', 'lessThan': '*', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MD84 (CP300)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MD85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MD86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MD89 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MD89 (CP300) V9.6x', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V9.68', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 6MU85 (CP300)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7KE85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SA82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SA82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SA86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SA87 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SD82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SD82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SD86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SD87 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ81 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ81 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SJ86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SK82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SK82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SK85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SL82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SL82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SL86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SL87 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SS85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7ST85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7ST85 (CP300) V9.6x', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V9.68', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7ST86 (CP300)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7ST86 (CP300) V9.8x', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V9.83', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SX82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SX85 (CP300)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7SY82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UM85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UT82 (CP100)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V8.90', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UT82 (CP150)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UT85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UT86 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7UT87 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7VE85 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7VK87 (CP300)', 'versions': [{'status': 'affected', 'version': 'V7.80', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 7VU85 (CP300)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}, {'vendor': 'Siemens', 'product': 'SIPROTEC 5 Compact 7SX800 (CP050)', 'versions': [{'status': 'affected', 'version': '0', 'lessThan': 'V10.0', 'versionType': 'custom'}], 'defaultStatus': 'unknown'}]
  • CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0

    Jun. 17, 2026

    Action Type Old Value New Value
    Added Affected [{'cpes': ['cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*'], 'vendor': 'ietf', 'product': 'rfc', 'versions': [{'status': 'affected', 'version': '2865'}], 'defaultStatus': 'unknown'}]
    Added SSVC {'id': 'CVE-2024-3596', 'role': 'CISA Coordinator', 'options': [{'exploitation': 'none'}, {'automatable': 'no'}, {'technicalImpact': 'total'}], 'version': '2.0.3', 'timestamp': '2024-07-11T03:55:37.141738Z'}
  • CVE Modified by 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e

    May. 12, 2026

    Action Type Old Value New Value
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-364175.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-770770.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 04, 2025

    Action Type Old Value New Value
    Added Reference https://www.kb.cert.org/vuls/id/456537
  • CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0

    Sep. 04, 2025

    Action Type Old Value New Value
    Removed CWE CWE-200
    Removed CWE CWE-328
    Removed CWE CWE-354
    Removed CWE CWE-924
  • CVE Modified by [email protected]

    Sep. 03, 2025

    Action Type Old Value New Value
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-723487.html
    Added Reference https://cert-portal.siemens.com/productcert/html/ssa-794185.html
  • CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0

    Mar. 18, 2025

    Action Type Old Value New Value
    Added CVSS V3.1 AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
    Added CWE CWE-200
    Added CWE CWE-328
    Added CWE CWE-354
    Added CWE CWE-924
  • Initial Analysis by [email protected]

    Dec. 30, 2024

    Action Type Old Value New Value
    Added CVSS V3.1 NIST AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
    Added CWE NIST CWE-354
    Added CWE NIST CWE-924
    Added CPE Configuration OR *cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:* *cpe:2.3:o:broadcom:fabric_operating_system:-:*:*:*:*:*:*:*
    Added CPE Configuration OR *cpe:2.3:a:freeradius:freeradius:*:*:*:*:*:*:*:* versions up to (excluding) 3.0.27
    Added CPE Configuration OR *cpe:2.3:o:sonicwall:sonicos:-:*:*:*:*:*:*:*
    Changed Reference Type http://www.openwall.com/lists/oss-security/2024/07/09/4 No Types Assigned http://www.openwall.com/lists/oss-security/2024/07/09/4 Mailing List
    Changed Reference Type http://www.openwall.com/lists/oss-security/2024/07/09/4 No Types Assigned http://www.openwall.com/lists/oss-security/2024/07/09/4 Mailing List
    Changed Reference Type https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ No Types Assigned https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Technical Description
    Changed Reference Type https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ No Types Assigned https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ Technical Description
    Changed Reference Type https://datatracker.ietf.org/doc/html/rfc2865 No Types Assigned https://datatracker.ietf.org/doc/html/rfc2865 Technical Description
    Changed Reference Type https://datatracker.ietf.org/doc/html/rfc2865 No Types Assigned https://datatracker.ietf.org/doc/html/rfc2865 Technical Description
    Changed Reference Type https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf No Types Assigned https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Third Party Advisory
    Changed Reference Type https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf No Types Assigned https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf Third Party Advisory
    Changed Reference Type https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 No Types Assigned https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Third Party Advisory
    Changed Reference Type https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 No Types Assigned https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 Third Party Advisory
    Changed Reference Type https://security.netapp.com/advisory/ntap-20240822-0001/ No Types Assigned https://security.netapp.com/advisory/ntap-20240822-0001/ Third Party Advisory
    Changed Reference Type https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol No Types Assigned https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol Third Party Advisory
    Changed Reference Type https://www.blastradius.fail/ No Types Assigned https://www.blastradius.fail/ Technical Description
    Changed Reference Type https://www.blastradius.fail/ No Types Assigned https://www.blastradius.fail/ Technical Description
  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference http://www.openwall.com/lists/oss-security/2024/07/09/4
    Added Reference https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/
    Added Reference https://datatracker.ietf.org/doc/html/rfc2865
    Added Reference https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf
    Added Reference https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014
    Added Reference https://security.netapp.com/advisory/ntap-20240822-0001/
    Added Reference https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol
    Added Reference https://www.blastradius.fail/
  • CVE Modified by [email protected]

    Jul. 23, 2024

    Action Type Old Value New Value
    Added Reference CERT/CC https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014 [No types assigned]
  • CVE Modified by [email protected]

    Jul. 09, 2024

    Action Type Old Value New Value
    Added Reference CERT/CC http://www.openwall.com/lists/oss-security/2024/07/09/4 [No types assigned]
  • CVE Modified by [email protected]

    Jul. 09, 2024

    Action Type Old Value New Value
    Removed Reference CERT/CC https://www.kb.cert.org/vuls/id/456537
  • CVE Modified by [email protected]

    Jul. 09, 2024

    Action Type Old Value New Value
    Added Reference CERT/CC https://www.kb.cert.org/vuls/id/456537 [No types assigned]
  • CVE Received by [email protected]

    Jul. 09, 2024

    Action Type Old Value New Value
    Added Description RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
    Added Reference CERT/CC https://datatracker.ietf.org/doc/html/rfc2865 [No types assigned]
    Added Reference CERT/CC https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/ [No types assigned]
    Added Reference CERT/CC https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf [No types assigned]
    Added Reference CERT/CC https://www.blastradius.fail/ [No types assigned]
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.