CVE-2024-4065
Tenda AC8 Stack-Based Buffer Overflow Vulnerability
Description
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
INFO
Published Date :
April 23, 2024, 8:15 p.m.
Last Modified :
Nov. 21, 2024, 9:42 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.8
Public PoC/Exploit Available at Github
CVE-2024-4065 has a 1 public PoC/Exploit
available at Github.
Go to the Public Exploits
tab to see the list.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-4065
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
None
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-4065
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2024-4065
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md Added Reference https://vuldb.com/?ctiid.261791 Added Reference https://vuldb.com/?id.261791 Added Reference https://vuldb.com/?submit.316494 -
CVE Modified by [email protected]
Jun. 04, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 17, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Received by [email protected]
Apr. 23, 2024
Action Type Old Value New Value Added Description A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Added Reference VulDB https://vuldb.com/?id.261791 [No types assigned] Added Reference VulDB https://vuldb.com/?ctiid.261791 [No types assigned] Added Reference VulDB https://vuldb.com/?submit.316494 [No types assigned] Added Reference VulDB https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md [No types assigned] Added CWE VulDB CWE-121 Added CVSS V2 VulDB (AV:N/AC:L/Au:S/C:C/I:C/A:C) Added CVSS V3.1 VulDB AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-4065
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-4065
weaknesses.