CVE-2024-43659
Plaintext default credentials in firmware
Description
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
INFO
Published Date :
Jan. 9, 2025, 8:15 a.m.
Last Modified :
Jan. 9, 2025, 3:15 p.m.
Remotely Exploit :
No
Source :
[email protected]
Affected Products
The following products are affected by CVE-2024-43659
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
---|---|---|---|---|---|---|
CVSS 3.1 | HIGH | 134c704f-9b21-4f2e-91b3-4a467353bcc0 | ||||
CVSS 4.0 | HIGH | [email protected] |
Solution
- Change the default password on all chargers.
- Update firmware on AC models to version 25010801 or later.
- Securely manage and rotate credentials regularly.
- Restrict access to firmware update mechanisms.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-43659
.
URL | Resource |
---|---|
https://csirt.divd.nl/CVE-2024-43659/ | |
https://csirt.divd.nl/DIVD-2024-00035/ | |
https://iocharger.com |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-43659
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-43659
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-43659
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2024-43659
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Jan. 09, 2025
Action Type Old Value New Value Added CVSS V3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H -
New CVE Received by [email protected]
Jan. 09, 2025
Action Type Old Value New Value Added Description After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). Added CVSS V4.0 AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:X/RE:X/U:X Added CWE CWE-256 Added CWE CWE-1391 Added CWE CWE-1393 Added Reference https://csirt.divd.nl/CVE-2024-43659/ Added Reference https://csirt.divd.nl/DIVD-2024-00035/ Added Reference https://iocharger.com