4.3
MEDIUM
CVE-2024-50560
Siemens Industrial Routers Username Truncation Vulnerability
Description

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity.

INFO

Published Date :

Nov. 12, 2024, 1:15 p.m.

Last Modified :

Nov. 13, 2024, 7:57 p.m.

Remotely Exploitable :

Yes !

Impact Score :

1.4

Exploitability Score :

2.8
Affected Products

The following products are affected by CVE-2024-50560 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens scalance_s615_firmware
2 Siemens scalance_m804pb_firmware
3 Siemens scalance_m826-2_firmware
4 Siemens scalance_m874-2_firmware
5 Siemens scalance_m874-3_firmware
6 Siemens scalance_m876-3_firmware
7 Siemens scalance_m876-4_firmware
8 Siemens ruggedcom_rm1224_lte\(4g\)_eu_firmware
9 Siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware
10 Siemens scalance_s615_eec_firmware
11 Siemens scalance_m804pb
12 Siemens scalance_m826-2
13 Siemens scalance_m874-2
14 Siemens scalance_m874-3
15 Siemens scalance_m876-3
16 Siemens scalance_m876-4
17 Siemens scalance_s615
18 Siemens ruggedcom_rm1224_lte\(4g\)_eu
19 Siemens ruggedcom_rm1224_lte\(4g\)_nam
20 Siemens scalance_s615_eec
21 Siemens scalance_m876-3_\(rok\)_firmware
22 Siemens scalance_m876-3_\(rok\)
23 Siemens scalance_m876-4_\(eu\)_firmware
24 Siemens scalance_m876-4_\(eu\)
25 Siemens scalance_m876-4_\(nam\)_firmware
26 Siemens scalance_m876-4_\(nam\)
27 Siemens scalance_mum853-1_\(a1\)_firmware
28 Siemens scalance_mum853-1_\(a1\)
29 Siemens scalance_mum853-1_\(b1\)_firmware
30 Siemens scalance_mum853-1_\(b1\)
31 Siemens scalance_mum853-1_\(eu\)_firmware
32 Siemens scalance_mum853-1_\(eu\)
33 Siemens scalance_mum856-1_\(a1\)_firmware
34 Siemens scalance_mum856-1_\(a1\)
35 Siemens scalance_mum856-1_\(b1\)_firmware
36 Siemens scalance_mum856-1_\(b1\)
37 Siemens scalance_mum856-1_\(cn\)_firmware
38 Siemens scalance_mum856-1_\(cn\)
39 Siemens scalance_mum856-1_\(eu\)_firmware
40 Siemens scalance_mum856-1_\(eu\)
41 Siemens scalance_mum856-1_\(row\)_firmware
42 Siemens scalance_mum856-1_\(row\)
43 Siemens scalance_m812-1_\(annex_a\)_firmware
44 Siemens scalance_m812-1_\(annex_a\)
45 Siemens scalance_m812-1_\(annex_b\)_firmware
46 Siemens scalance_m812-1_\(annex_b\)
47 Siemens scalance_m816-1_\(annex_a\)_firmware
48 Siemens scalance_m816-1_\(annex_a\)
49 Siemens scalance_m816-1_\(annex_b\)_firmware
50 Siemens scalance_m816-1_\(annex_b\)
51 Siemens scalance_m874-3_\(cn\)_firmware
52 Siemens scalance_m874-3_\(cn\)
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2024-50560.

URL Resource
https://cert-portal.siemens.com/productcert/html/ssa-354112.html Patch Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2024-50560 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2024-50560 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • Initial Analysis by [email protected]

    Nov. 13, 2024

    Action Type Old Value New Value
    Added CVSS V3.1 NIST AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
    Changed Reference Type https://cert-portal.siemens.com/productcert/html/ssa-354112.html No Types Assigned https://cert-portal.siemens.com/productcert/html/ssa-354112.html Patch, Vendor Advisory
    Added CWE NIST NVD-CWE-noinfo
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_eu:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_nam:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m812-1_\(annex_a\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m812-1_\(annex_b\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m816-1_\(annex_a\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m816-1_\(annex_b\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m826-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-3_\(cn\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-3_\(cn\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-3_\(rok\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4_\(nam\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(a1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(b1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(a1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(b1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(cn\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(row\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*
  • CVE Received by [email protected]

    Nov. 12, 2024

    Action Type Old Value New Value
    Added Description A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity.
    Added Reference Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-354112.html [No types assigned]
    Added CWE Siemens AG CWE-20
    Added CVSS V3.1 Siemens AG AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N
    Added CVSS V4.0 Siemens AG CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2024-50560 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2024-50560 weaknesses.

CAPEC-3: Using Leading 'Ghost' Character Sequences to Bypass Input Filters Using Leading 'Ghost' Character Sequences to Bypass Input Filters CAPEC-7: Blind SQL Injection Blind SQL Injection CAPEC-8: Buffer Overflow in an API Call Buffer Overflow in an API Call CAPEC-9: Buffer Overflow in Local Command-Line Utilities Buffer Overflow in Local Command-Line Utilities CAPEC-10: Buffer Overflow via Environment Variables Buffer Overflow via Environment Variables CAPEC-13: Subverting Environment Variable Values Subverting Environment Variable Values CAPEC-14: Client-side Injection-induced Buffer Overflow Client-side Injection-induced Buffer Overflow CAPEC-22: Exploiting Trust in Client Exploiting Trust in Client CAPEC-23: File Content Injection File Content Injection CAPEC-24: Filter Failure through Buffer Overflow Filter Failure through Buffer Overflow CAPEC-28: Fuzzing Fuzzing CAPEC-31: Accessing/Intercepting/Modifying HTTP Cookies Accessing/Intercepting/Modifying HTTP Cookies CAPEC-42: MIME Conversion MIME Conversion CAPEC-43: Exploiting Multiple Input Interpretation Layers Exploiting Multiple Input Interpretation Layers CAPEC-45: Buffer Overflow via Symbolic Links Buffer Overflow via Symbolic Links CAPEC-46: Overflow Variables and Tags Overflow Variables and Tags CAPEC-47: Buffer Overflow via Parameter Expansion Buffer Overflow via Parameter Expansion CAPEC-52: Embedding NULL Bytes Embedding NULL Bytes CAPEC-53: Postfix, Null Terminate, and Backslash Postfix, Null Terminate, and Backslash CAPEC-63: Cross-Site Scripting (XSS) Cross-Site Scripting (XSS) CAPEC-64: Using Slashes and URL Encoding Combined to Bypass Validation Logic Using Slashes and URL Encoding Combined to Bypass Validation Logic CAPEC-67: String Format Overflow in syslog() String Format Overflow in syslog() CAPEC-71: Using Unicode Encoding to Bypass Validation Logic Using Unicode Encoding to Bypass Validation Logic CAPEC-72: URL Encoding URL Encoding CAPEC-73: User-Controlled Filename User-Controlled Filename CAPEC-78: Using Escaped Slashes in Alternate Encoding Using Escaped Slashes in Alternate Encoding CAPEC-79: Using Slashes in Alternate Encoding Using Slashes in Alternate Encoding CAPEC-80: Using UTF-8 Encoding to Bypass Validation Logic Using UTF-8 Encoding to Bypass Validation Logic CAPEC-81: Web Server Logs Tampering Web Server Logs Tampering CAPEC-83: XPath Injection XPath Injection CAPEC-85: AJAX Footprinting AJAX Footprinting CAPEC-88: OS Command Injection OS Command Injection CAPEC-101: Server Side Include (SSI) Injection Server Side Include (SSI) Injection CAPEC-104: Cross Zone Scripting Cross Zone Scripting CAPEC-108: Command Line Execution through SQL Injection Command Line Execution through SQL Injection CAPEC-109: Object Relational Mapping Injection Object Relational Mapping Injection CAPEC-110: SQL Injection through SOAP Parameter Tampering SQL Injection through SOAP Parameter Tampering CAPEC-120: Double Encoding Double Encoding CAPEC-135: Format String Injection Format String Injection CAPEC-136: LDAP Injection LDAP Injection CAPEC-153: Input Data Manipulation Input Data Manipulation CAPEC-182: Flash Injection Flash Injection CAPEC-209: XSS Using MIME Type Mismatch XSS Using MIME Type Mismatch CAPEC-230: Serialized Data with Nested Payloads Serialized Data with Nested Payloads CAPEC-231: Oversized Serialized Data Payloads Oversized Serialized Data Payloads CAPEC-250: XML Injection XML Injection CAPEC-261: Fuzzing for garnering other adjacent user/sensitive data Fuzzing for garnering other adjacent user/sensitive data CAPEC-267: Leverage Alternate Encoding Leverage Alternate Encoding CAPEC-473: Signature Spoof Signature Spoof CAPEC-588: DOM-Based XSS DOM-Based XSS CAPEC-664: Server Side Request Forgery Server Side Request Forgery
CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability