7.2
HIGH
CVE-2024-50572
Siemens RUGGEDCOM and SCALANCE Remote Code Execution Vulnerability
Description

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

INFO

Published Date :

Nov. 12, 2024, 1:15 p.m.

Last Modified :

Nov. 13, 2024, 7:59 p.m.

Remotely Exploitable :

Yes !

Impact Score :

5.9

Exploitability Score :

1.2
Affected Products

The following products are affected by CVE-2024-50572 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens scalance_s615_firmware
2 Siemens scalance_m804pb_firmware
3 Siemens scalance_m826-2_firmware
4 Siemens scalance_m874-2_firmware
5 Siemens scalance_m874-3_firmware
6 Siemens scalance_m876-3_firmware
7 Siemens scalance_m876-4_firmware
8 Siemens ruggedcom_rm1224_lte\(4g\)_eu_firmware
9 Siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware
10 Siemens scalance_s615_eec_firmware
11 Siemens scalance_m804pb
12 Siemens scalance_m826-2
13 Siemens scalance_m874-2
14 Siemens scalance_m874-3
15 Siemens scalance_m876-3
16 Siemens scalance_m876-4
17 Siemens scalance_s615
18 Siemens ruggedcom_rm1224_lte\(4g\)_eu
19 Siemens ruggedcom_rm1224_lte\(4g\)_nam
20 Siemens scalance_s615_eec
21 Siemens scalance_m876-3_\(rok\)_firmware
22 Siemens scalance_m876-3_\(rok\)
23 Siemens scalance_m876-4_\(eu\)_firmware
24 Siemens scalance_m876-4_\(eu\)
25 Siemens scalance_m876-4_\(nam\)_firmware
26 Siemens scalance_m876-4_\(nam\)
27 Siemens scalance_mum853-1_\(a1\)_firmware
28 Siemens scalance_mum853-1_\(a1\)
29 Siemens scalance_mum853-1_\(b1\)_firmware
30 Siemens scalance_mum853-1_\(b1\)
31 Siemens scalance_mum853-1_\(eu\)_firmware
32 Siemens scalance_mum853-1_\(eu\)
33 Siemens scalance_mum856-1_\(a1\)_firmware
34 Siemens scalance_mum856-1_\(a1\)
35 Siemens scalance_mum856-1_\(b1\)_firmware
36 Siemens scalance_mum856-1_\(b1\)
37 Siemens scalance_mum856-1_\(cn\)_firmware
38 Siemens scalance_mum856-1_\(cn\)
39 Siemens scalance_mum856-1_\(eu\)_firmware
40 Siemens scalance_mum856-1_\(eu\)
41 Siemens scalance_mum856-1_\(row\)_firmware
42 Siemens scalance_mum856-1_\(row\)
43 Siemens scalance_m812-1_\(annex_a\)_firmware
44 Siemens scalance_m812-1_\(annex_a\)
45 Siemens scalance_m812-1_\(annex_b\)_firmware
46 Siemens scalance_m812-1_\(annex_b\)
47 Siemens scalance_m816-1_\(annex_a\)_firmware
48 Siemens scalance_m816-1_\(annex_a\)
49 Siemens scalance_m816-1_\(annex_b\)_firmware
50 Siemens scalance_m816-1_\(annex_b\)
51 Siemens scalance_m874-3_\(cn\)_firmware
52 Siemens scalance_m874-3_\(cn\)
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2024-50572.

URL Resource
https://cert-portal.siemens.com/productcert/html/ssa-354112.html Patch Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2024-50572 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2024-50572 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • Initial Analysis by [email protected]

    Nov. 13, 2024

    Action Type Old Value New Value
    Changed Reference Type https://cert-portal.siemens.com/productcert/html/ssa-354112.html No Types Assigned https://cert-portal.siemens.com/productcert/html/ssa-354112.html Patch, Vendor Advisory
    Added CWE NIST CWE-77
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_eu:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_nam:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m812-1_\(annex_a\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m812-1_\(annex_b\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m816-1_\(annex_a\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m816-1_\(annex_b\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m826-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m874-3_\(cn\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m874-3_\(cn\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-3_\(rok\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_m876-4_\(nam\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(a1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(b1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum853-1_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(a1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(b1\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(cn\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(eu\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_mum856-1_\(row\):-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 8.2 OR cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*
  • CVE Received by [email protected]

    Nov. 12, 2024

    Action Type Old Value New Value
    Added Description A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
    Added Reference Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-354112.html [No types assigned]
    Added CWE Siemens AG CWE-74
    Added CVSS V3.1 Siemens AG AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
    Added CVSS V4.0 Siemens AG CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2024-50572 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2024-50572 weaknesses.

CAPEC-3: Using Leading 'Ghost' Character Sequences to Bypass Input Filters Using Leading 'Ghost' Character Sequences to Bypass Input Filters CAPEC-6: Argument Injection Argument Injection CAPEC-7: Blind SQL Injection Blind SQL Injection CAPEC-8: Buffer Overflow in an API Call Buffer Overflow in an API Call CAPEC-9: Buffer Overflow in Local Command-Line Utilities Buffer Overflow in Local Command-Line Utilities CAPEC-10: Buffer Overflow via Environment Variables Buffer Overflow via Environment Variables CAPEC-13: Subverting Environment Variable Values Subverting Environment Variable Values CAPEC-14: Client-side Injection-induced Buffer Overflow Client-side Injection-induced Buffer Overflow CAPEC-24: Filter Failure through Buffer Overflow Filter Failure through Buffer Overflow CAPEC-28: Fuzzing Fuzzing CAPEC-34: HTTP Response Splitting HTTP Response Splitting CAPEC-42: MIME Conversion MIME Conversion CAPEC-43: Exploiting Multiple Input Interpretation Layers Exploiting Multiple Input Interpretation Layers CAPEC-45: Buffer Overflow via Symbolic Links Buffer Overflow via Symbolic Links CAPEC-46: Overflow Variables and Tags Overflow Variables and Tags CAPEC-47: Buffer Overflow via Parameter Expansion Buffer Overflow via Parameter Expansion CAPEC-51: Poison Web Service Registry Poison Web Service Registry CAPEC-52: Embedding NULL Bytes Embedding NULL Bytes CAPEC-53: Postfix, Null Terminate, and Backslash Postfix, Null Terminate, and Backslash CAPEC-64: Using Slashes and URL Encoding Combined to Bypass Validation Logic Using Slashes and URL Encoding Combined to Bypass Validation Logic CAPEC-67: String Format Overflow in syslog() String Format Overflow in syslog() CAPEC-71: Using Unicode Encoding to Bypass Validation Logic Using Unicode Encoding to Bypass Validation Logic CAPEC-72: URL Encoding URL Encoding CAPEC-76: Manipulating Web Input to File System Calls Manipulating Web Input to File System Calls CAPEC-78: Using Escaped Slashes in Alternate Encoding Using Escaped Slashes in Alternate Encoding CAPEC-79: Using Slashes in Alternate Encoding Using Slashes in Alternate Encoding CAPEC-80: Using UTF-8 Encoding to Bypass Validation Logic Using UTF-8 Encoding to Bypass Validation Logic CAPEC-83: XPath Injection XPath Injection CAPEC-84: XQuery Injection XQuery Injection CAPEC-101: Server Side Include (SSI) Injection Server Side Include (SSI) Injection CAPEC-105: HTTP Request Splitting HTTP Request Splitting CAPEC-108: Command Line Execution through SQL Injection Command Line Execution through SQL Injection CAPEC-120: Double Encoding Double Encoding CAPEC-135: Format String Injection Format String Injection CAPEC-250: XML Injection XML Injection CAPEC-267: Leverage Alternate Encoding Leverage Alternate Encoding CAPEC-273: HTTP Response Smuggling HTTP Response Smuggling CAPEC-15: Command Delimiters Command Delimiters CAPEC-40: Manipulating Writeable Terminal Devices Manipulating Writeable Terminal Devices CAPEC-43: Exploiting Multiple Input Interpretation Layers Exploiting Multiple Input Interpretation Layers CAPEC-75: Manipulating Writeable Configuration Files Manipulating Writeable Configuration Files CAPEC-76: Manipulating Web Input to File System Calls Manipulating Web Input to File System Calls CAPEC-136: LDAP Injection LDAP Injection CAPEC-183: IMAP/SMTP Command Injection IMAP/SMTP Command Injection CAPEC-248: Command Injection Command Injection
CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability