CVE-2024-6189
Tenda A301 Stack-Based Buffer Overflow Vulnerability
Description
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
INFO
Published Date :
June 20, 2024, 2:15 p.m.
Last Modified :
Nov. 21, 2024, 9:49 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.8
Public PoC/Exploit Available at Github
CVE-2024-6189 has a 1 public PoC/Exploit
available at Github.
Go to the Public Exploits
tab to see the list.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-6189
.
URL | Resource |
---|---|
https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd | Exploit Third Party Advisory |
https://vuldb.com/?ctiid.269160 | Permissions Required VDB Entry |
https://vuldb.com/?id.269160 | Third Party Advisory VDB Entry |
https://vuldb.com/?submit.355264 | Third Party Advisory VDB Entry |
https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd | Exploit Third Party Advisory |
https://vuldb.com/?ctiid.269160 | Permissions Required VDB Entry |
https://vuldb.com/?id.269160 | Third Party Advisory VDB Entry |
https://vuldb.com/?submit.355264 | Third Party Advisory VDB Entry |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
None
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-6189
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2024-6189
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd Added Reference https://vuldb.com/?ctiid.269160 Added Reference https://vuldb.com/?id.269160 Added Reference https://vuldb.com/?submit.355264 -
Initial Analysis by [email protected]
Nov. 01, 2024
Action Type Old Value New Value Added CVSS V3.1 NIST AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd No Types Assigned https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd Exploit, Third Party Advisory Changed Reference Type https://vuldb.com/?ctiid.269160 No Types Assigned https://vuldb.com/?ctiid.269160 Permissions Required, VDB Entry Changed Reference Type https://vuldb.com/?id.269160 No Types Assigned https://vuldb.com/?id.269160 Third Party Advisory, VDB Entry Changed Reference Type https://vuldb.com/?submit.355264 No Types Assigned https://vuldb.com/?submit.355264 Third Party Advisory, VDB Entry Added CWE NIST CWE-787 Added CPE Configuration AND OR *cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:* OR cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:* -
CVE Modified by [email protected]
Jun. 25, 2024
Action Type Old Value New Value -
CVE Received by [email protected]
Jun. 20, 2024
Action Type Old Value New Value Added Description A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Added Reference VulDB https://vuldb.com/?id.269160 [No types assigned] Added Reference VulDB https://vuldb.com/?ctiid.269160 [No types assigned] Added Reference VulDB https://vuldb.com/?submit.355264 [No types assigned] Added Reference VulDB https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd [No types assigned] Added CWE VulDB CWE-121 Added CVSS V2 VulDB (AV:N/AC:L/Au:S/C:C/I:C/A:C) Added CVSS V3.1 VulDB AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Added CVSS V4.0 VulDB CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-6189
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-6189
weaknesses.