CVE-2024-6795
Connex Health Portal SQL Injection Vulnerability
Description
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database. An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database.
INFO
Published Date :
Sept. 9, 2024, 8:15 p.m.
Last Modified :
Sept. 20, 2024, 2:53 p.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
6.0
Exploitability Score :
3.9
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2024-6795
.
URL | Resource |
---|---|
https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01 | Third Party Advisory US Government Resource |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2024-6795
vulnerability anywhere in the article.
- Dark Reading
CISA Flags ICS Bugs in Baxter, Mitsubishi Products
Source: PopTika via ShutterstockThis week the US Cybersecurity and Infrastructure Security Agency (CISA) warned about two new industrial control systems (ICS) vulnerabilities in products widely used i ... Read more
The following table lists the changes that have been made to the
CVE-2024-6795
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
Initial Analysis by [email protected]
Sep. 20, 2024
Action Type Old Value New Value Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01 No Types Assigned https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01 Third Party Advisory, US Government Resource Added CWE NIST CWE-89 Added CPE Configuration OR *cpe:2.3:a:baxter:connex_health_portal:*:*:*:*:*:*:*:* versions up to (excluding) 2024-08-30 -
CVE Received by [email protected]
Sep. 09, 2024
Action Type Old Value New Value Added Description In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthorized access to Connex portal's database. An attacker could have submitted a crafted payload to Connex portal that could have resulted in modification and disclosure of database content and/or perform administrative operations including shutting down the database. Added Reference Baxter https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01 [No types assigned] Added CWE Baxter CWE-89 Added CVSS V3.1 Baxter AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2024-6795
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2024-6795
weaknesses.