CVE-2025-57215
Tenda AC10 Stack Overflow Vulnerability
Description
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info.
INFO
Published Date :
Aug. 28, 2025, 7:15 p.m.
Last Modified :
Sept. 3, 2025, 4:11 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
CVSS Scores
Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
---|---|---|---|---|---|---|
CVSS 3.1 | HIGH | 134c704f-9b21-4f2e-91b3-4a467353bcc0 |
Solution
- Update the Tenda AC10 v4.0 firmware to a newer version.
- Apply patches provided by the vendor.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2025-57215
.
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2025-57215
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2025-57215
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2025-57215
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2025-57215
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
Initial Analysis by [email protected]
Sep. 03, 2025
Action Type Old Value New Value Added CPE Configuration AND OR *cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:* OR cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:* Added Reference Type MITRE: https://plaid-knot-11b.notion.site/Heap-based-Buffer-Overflow-in-function-get_parentControl_list_Info-via-deviceId-parameter-Remote-at-23eb3e9cce328014a639f619bc14ed90 Types: Third Party Advisory Added Reference Type MITRE: https://www.tenda.com.cn Types: Product -
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Aug. 28, 2025
Action Type Old Value New Value Added CVSS V3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Added CWE CWE-121 -
New CVE Received by [email protected]
Aug. 28, 2025
Action Type Old Value New Value Added Description Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info. Added Reference https://plaid-knot-11b.notion.site/Heap-based-Buffer-Overflow-in-function-get_parentControl_list_Info-via-deviceId-parameter-Remote-at-23eb3e9cce328014a639f619bc14ed90 Added Reference https://www.tenda.com.cn