7.2
HIGH CVSS 3.1
CVE-2025-5965
RCE via the backup feature available only to user with high privilege
Description

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

INFO

Published Date :

Jan. 5, 2026, 10:15 a.m.

Last Modified :

Jan. 5, 2026, 10:15 a.m.

Remotely Exploit :

Yes !

Source :

bd4443e6-1eef-43f3-9886-25fc9ceeaae7
Affected Products

The following products are affected by CVE-2025-5965 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 HIGH bd4443e6-1eef-43f3-9886-25fc9ceeaae7
Solution
Update to a patched version to prevent OS command injection through backup configuration.
  • Update Centreon Infra Monitoring to a patched version.
  • Apply vendor-provided patches for the backup module.
  • Review and sanitize backup configuration inputs.
  • Restrict high privilege user access.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2025-5965.

URL Resource
https://github.com/centreon/centreon/releases
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2025-5965 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2025-5965 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2025-5965 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by bd4443e6-1eef-43f3-9886-25fc9ceeaae7

    Jan. 05, 2026

    Action Type Old Value New Value
    Added Description In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
    Added CVSS V3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
    Added CWE CWE-78
    Added Reference https://github.com/centreon/centreon/releases
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
Vulnerability Scoring Details
Base CVSS Score: 7.2
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality Impact
Integrity Impact
Availability Impact