CVE-2025-7970
Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability
Description
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.
INFO
Published Date :
Sept. 9, 2025, 1:15 p.m.
Last Modified :
Sept. 17, 2025, 3:59 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
                                            The following products are affected by CVE-2025-7970
                                            vulnerability.
                                            Even if cvefeed.io is aware of the exact versions of the
                                            products
                                            that
                                            are
                                            affected, the information is not represented in the table below.
                                        
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source | 
|---|---|---|---|---|---|---|
| CVSS 3.1 | HIGH | [email protected] | ||||
| CVSS 4.0 | HIGH | b73dd486-f505-4403-b634-40b078b177f0 | ||||
| CVSS 4.0 | HIGH | [email protected] | 
Solution
- Update FactoryTalk Activation Manager to the latest version.
- Apply any available security patches or hotfixes.
- Review and strengthen cryptographic configurations.
- Monitor network traffic for suspicious activity.
References to Advisories, Solutions, and Tools
                                            Here, you will find a curated list of external links that provide in-depth
                                            information, practical solutions, and valuable tools related to
                                            CVE-2025-7970.
                                        
| URL | Resource | 
|---|---|
| https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1741.html | Vendor Advisory | 
CWE - Common Weakness Enumeration
            While CVE identifies
            specific instances of vulnerabilities, CWE categorizes the common flaws or
            weaknesses that can lead to vulnerabilities. CVE-2025-7970 is
            associated with the following CWEs:
        
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
            (CAPEC)
            stores attack patterns, which are descriptions of the common attributes and
            approaches employed by adversaries to exploit the CVE-2025-7970
            weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
			The following list is the news that have been mention
			CVE-2025-7970 vulnerability anywhere in the article.
		
                The following table lists the changes that have been made to the
                CVE-2025-7970 vulnerability over time.
            
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
- 
                            Initial Analysis by [email protected]Sep. 17, 2025 Action Type Old Value New Value Added CVSS V3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Added CPE Configuration OR *cpe:2.3:a:rockwellautomation:factorytalk_activation_manager:*:*:*:*:*:*:*:* versions from (including) 5.00.00 up to (including) 5.01.01 Added Reference Type Rockwell Automation: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1741.html Types: Vendor Advisory 
- 
                            New CVE Received by [email protected]Sep. 09, 2025 Action Type Old Value New Value Added Description A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-306 Added Reference https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1741.html 
 
                         
                         
                         
                                             
                                            