CVE-2025-9437
Rockwell Automation ArmorStart® AOP Denial-of-Service Vulnerability
Description
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
INFO
Published Date :
Oct. 14, 2025, 12:15 p.m.
Last Modified :
Oct. 14, 2025, 7:36 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2025-9437
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
---|---|---|---|---|---|---|
CVSS 4.0 | HIGH | b73dd486-f505-4403-b634-40b078b177f0 | ||||
CVSS 4.0 | HIGH | [email protected] |
Solution
- Update Studio 5000 Logix Designer add-on profile.
- Validate inputs to COM methods.
- Install vendor-provided security patches.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2025-9437
.
URL | Resource |
---|---|
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1751.html |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2025-9437
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2025-9437
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2025-9437
vulnerability anywhere in the article.

-
Daily CyberSecurity
Rockwell Automation Patches Privilege Escalation and Denial-of-Service Flaws Across FactoryTalk and ArmorStart Systems
Rockwell Automation has released a series of security advisories addressing vulnerabilities in several of its FactoryTalk and ArmorStart product lines. These flaws, discovered through internal testing ... Read more
The following table lists the changes that have been made to the
CVE-2025-9437
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Oct. 14, 2025
Action Type Old Value New Value Added Description A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-755 Added Reference https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1751.html