CVE-2026-100684
Budibase Server 3.41.0 before 3.45.0 Authentication Bypass via OIDC
Description
Budibase versions 3.41.0 before 3.45.0 contain an authentication bypass in the OIDC/SSO login path of @budibase/server. In sso.authenticate, when no existing user matches the incoming SSO subject, the server looks up pending user invites by the IdP-asserted email address alone — without validating an invite code and without an email_verified check (the email_verified gate protects only the existing-account lookup). An attacker who can register at an IdP that the tenant trusts for OIDC and assert a victim's invited email address (even with email_verified=false) claims the pending invite and inherits all of its granted privileges, including builder and admin.global, with no admin exclusion. This results in takeover of the invited principal and, for admin invites, full tenant compromise (access to all apps, datasources including production credentials, and automations); the invite is consumed, denying onboarding to the legitimate invitee.
INFO
Published Date :
Sept. 26, 2026, 2:16 p.m.
Last Modified :
Sept. 26, 2026, 2:16 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2026-100684
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 3.1 | HIGH | 83251b91-4cc7-4094-a5c7-464a1b83ea10 | ||||
| CVSS 3.1 | HIGH | MITRE-CVE | ||||
| CVSS 3.1 | HIGH | [email protected] | ||||
| CVSS 4.0 | CRITICAL | 83251b91-4cc7-4094-a5c7-464a1b83ea10 | ||||
| CVSS 4.0 | CRITICAL | [email protected] |
Solution
- Update Budibase to version 3.45.0 or later.
- Verify OIDC/SSO configuration and user invite processes.
- Review existing user privileges and audit access logs.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-100684.
| URL | Resource |
|---|---|
| https://github.com/Budibase/budibase/security/advisories/GHSA-35ch-57g2-3g98 | |
| https://www.vulncheck.com/advisories/budibase-server-3.41.0-before-3.45.0-authentication-bypass-via-oidc |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-100684 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-100684
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-100684 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-100684 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Sep. 26, 2026
Action Type Old Value New Value Added Description Budibase versions 3.41.0 before 3.45.0 contain an authentication bypass in the OIDC/SSO login path of @budibase/server. In sso.authenticate, when no existing user matches the incoming SSO subject, the server looks up pending user invites by the IdP-asserted email address alone — without validating an invite code and without an email_verified check (the email_verified gate protects only the existing-account lookup). An attacker who can register at an IdP that the tenant trusts for OIDC and assert a victim's invited email address (even with email_verified=false) claims the pending invite and inherits all of its granted privileges, including builder and admin.global, with no admin exclusion. This results in takeover of the invited principal and, for admin invites, full tenant compromise (access to all apps, datasources including production credentials, and automations); the invite is consumed, denying onboarding to the legitimate invitee. Added CVSS V4.0 AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CVSS V3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H Added CWE CWE-287 Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/100xxx/CVE-2026-100684.json">CVE-2026-100684</a> Added Reference https://github.com/Budibase/budibase/security/advisories/GHSA-35ch-57g2-3g98 Added Reference https://www.vulncheck.com/advisories/budibase-server-3.41.0-before-3.45.0-authentication-bypass-via-oidc