CVE-2026-10577
Rockwell Automation 1715 Redundant IO – Access Control Vulnerability
Description
A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device.
INFO
Published Date :
July 14, 2026, 1:18 p.m.
Last Modified :
July 14, 2026, 2:16 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2026-10577
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS | 134c704f-9b21-4f2e-91b3-4a467353bcc0 | |||||
| CVSS 4.0 | CRITICAL | b73dd486-f505-4403-b634-40b078b177f0 | ||||
| CVSS 4.0 | CRITICAL | [email protected] |
Solution
- Disable the network-accessible debug port.
- Implement strict access controls for debug functionalities.
- Apply vendor security updates when available.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-10577.
| URL | Resource |
|---|---|
| https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-10577 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-10577
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-10577 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-10577 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Jul. 14, 2026
Action Type Old Value New Value Added SSVC {'id': 'CVE-2026-10577', 'role': 'CISA Coordinator', 'options': [{'exploitation': 'none'}, {'automatable': 'yes'}, {'technicalImpact': 'total'}], 'version': '2.0.3', 'timestamp': '2026-07-14T13:19:42.350747Z'} -
New CVE Received by [email protected]
Jul. 14, 2026
Action Type Old Value New Value Added Affected [{'vendor': 'Rockwell Auotmation', 'product': '1715 EtherNet/IP Communications Module', 'versions': [{'status': 'affected', 'version': '3.003 and prior'}], 'defaultStatus': 'unaffected'}] Added Description A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-306 Added Reference https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html