8.8
HIGH CVSS 3.1
CVE-2026-116786
FreeSWITCH: Channel-variable injection via SIP REFER leads to command execution in mod_sofia
Description

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, sofia_handle_sip_i_refer() placed raw Refer-To URI parameters and headers inside a sip_invite_params channel-variable block passed to switch_ivr_originate(). The originate parser treated a comma in the attacker-controlled value as a variable separator, allowing an authenticated caller on a bridged call to inject arbitrary variables into a newly originated leg. An injected execute_on_originate value could invoke the system dialplan application before answer and execute operating-system commands with the FreeSWITCH process privileges. SIP REFER is enabled by default, and the sender needs only a registered account and a call that takes the off-box transfer path, not administrative or Event Socket access. This issue is fixed in version 1.11.2.

INFO

Published Date :

Nov. 5, 2026, 8:17 p.m.

Last Modified :

Nov. 5, 2026, 8:17 p.m.

Remotely Exploit :

Yes !
Affected Products

The following products are affected by CVE-2026-116786 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Signalwire freeswitch
CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 HIGH [email protected]
Solution
Update FreeSWITCH to version 1.11.2 or later to fix an arbitrary variable injection vulnerability.
  • Update FreeSWITCH to version 1.11.2 or later.
  • Verify SIP REFER handling in channel variables.
  • Restrict access to SIP REFER functionality.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2026-116786.

URL Resource
https://github.com/signalwire/freeswitch/commit/fbac12b451a146fdac5104d25d337145be989e84
https://github.com/signalwire/freeswitch/releases/tag/v1.11.2
https://github.com/signalwire/freeswitch/security/advisories/GHSA-xjxm-9qx6-w3fj
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-116786 is associated with the following CWEs:

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-116786 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-116786 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Nov. 05, 2026

    Action Type Old Value New Value
    Added Description FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, sofia_handle_sip_i_refer() placed raw Refer-To URI parameters and headers inside a sip_invite_params channel-variable block passed to switch_ivr_originate(). The originate parser treated a comma in the attacker-controlled value as a variable separator, allowing an authenticated caller on a bridged call to inject arbitrary variables into a newly originated leg. An injected execute_on_originate value could invoke the system dialplan application before answer and execute operating-system commands with the FreeSWITCH process privileges. SIP REFER is enabled by default, and the sender needs only a registered account and a call that takes the off-box transfer path, not administrative or Event Socket access. This issue is fixed in version 1.11.2.
    Added CVSS V3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
    Added CWE CWE-94
    Added CWE CWE-77
    Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/116xxx/CVE-2026-116786.json">CVE-2026-116786</a>
    Added Reference https://github.com/signalwire/freeswitch/commit/fbac12b451a146fdac5104d25d337145be989e84
    Added Reference https://github.com/signalwire/freeswitch/releases/tag/v1.11.2
    Added Reference https://github.com/signalwire/freeswitch/security/advisories/GHSA-xjxm-9qx6-w3fj
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.