CVE-2026-120295
Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware
Description
Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
INFO
Published Date :
Nov. 10, 2026, 11:16 a.m.
Last Modified :
Nov. 10, 2026, 11:16 a.m.
Remotely Exploit :
Yes !
Source :
6b3ad84c-e1a6-4bf7-a703-f496b71e49db
Affected Products
The following products are affected by CVE-2026-120295
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 4.0 | HIGH | 6b3ad84c-e1a6-4bf7-a703-f496b71e49db | ||||
| CVSS 4.0 | HIGH | 6b3ad84c-e1a6-4bf7-a703-f496b71e49db |
Solution
- Update nerves_hub_web to version 2.5.3 or later.
- Ensure API checks authorization for target organization.
- Restrict device move to users with manage role.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-120295.
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-120295 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-120295
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-120295 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-120295 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by 6b3ad84c-e1a6-4bf7-a703-f496b71e49db
Nov. 10, 2026
Action Type Old Value New Value Added Description Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-863 Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/120xxx/CVE-2026-120295.json">CVE-2026-120295</a> Added Reference https://cna.erlef.org/cves/CVE-2026-120295.html Added Reference https://github.com/nerves-hub/nerves_hub_web/commit/1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa Added Reference https://github.com/nerves-hub/nerves_hub_web/commit/79743ef08f7f801617b653fd09f37c01ed9b4be0 Added Reference https://github.com/nerves-hub/nerves_hub_web/commit/adaeefdb7a835525482588f43332ef988cc448c7 Added Reference https://github.com/nerves-hub/nerves_hub_web/security/advisories/GHSA-2j7r-q3vm-8j34 Added Reference https://osv.dev/vulnerability/EEF-CVE-2026-120295