9.9
CRITICAL CVSS 3.1
CVE-2026-135788
D-Link DIR-X1860 anweb os command injection
Description

A weakness has been identified in D-Link DIR-X1860 4.5.2. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/anweb. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

INFO

Published Date :

Nov. 24, 2026, 5:18 p.m.

Last Modified :

Nov. 24, 2026, 5:18 p.m.

Remotely Exploit :

Yes !
Affected Products

The following products are affected by CVE-2026-135788 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 D-link dir-x1860
CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 2.0 HIGH [email protected]
CVSS 3.1 CRITICAL [email protected]
CVSS 4.0 HIGH [email protected]
Solution
Address OS command injection by updating firmware and restricting access.
  • Update the device firmware.
  • Restrict remote access to the device.
  • Validate all user inputs.
References to Advisories, Solutions, and Tools
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-135788 is associated with the following CWEs:

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-135788 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-135788 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Nov. 24, 2026

    Action Type Old Value New Value
    Added Description A weakness has been identified in D-Link DIR-X1860 4.5.2. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/anweb. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
    Added CVSS V4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CVSS V3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
    Added CVSS V2 (AV:N/AC:L/Au:S/C:C/I:C/A:C)
    Added CWE CWE-78
    Added CWE CWE-77
    Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/135xxx/CVE-2026-135788.json">CVE-2026-135788</a>
    Added Reference https://github.com/nenghun/IoT/blob/main/D-Link%20DIR%20X1860/D-Link%20DIR-X1860%204.5.2%20rce.md
    Added Reference https://vuldb.com/cve/CVE-2026-135788
    Added Reference https://vuldb.com/submit/1055809
    Added Reference https://vuldb.com/vuln/442751
    Added Reference https://vuldb.com/vuln/442751/cti
    Added Reference https://www.dlink.com/