CVE-2026-15570
Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command
Description
An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.
INFO
Published Date :
Aug. 7, 2026, 2:16 p.m.
Last Modified :
Aug. 7, 2026, 3:16 p.m.
Remotely Exploit :
No
Source :
5431be70-064b-4f6a-be51-69eacabef109
Affected Products
The following products are affected by CVE-2026-15570
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS | 134c704f-9b21-4f2e-91b3-4a467353bcc0 | |||||
| CVSS 4.0 | HIGH | 5431be70-064b-4f6a-be51-69eacabef109 | ||||
| CVSS 4.0 | HIGH | 5431be70-064b-4f6a-be51-69eacabef109 |
Solution
- Update firmware to version V2.85.2.0 or later.
- Verify that the browserseturl command restrictions are enforced.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-15570.
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-15570 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-15570
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-15570 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-15570 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0
Aug. 07, 2026
Action Type Old Value New Value Added SSVC {'id': 'CVE-2026-15570', 'role': 'CISA Coordinator', 'options': [{'exploitation': 'none'}, {'automatable': 'no'}, {'technicalImpact': 'partial'}], 'version': '2.0.3', 'timestamp': '2026-08-07T14:25:53.841501Z'} -
New CVE Received by 5431be70-064b-4f6a-be51-69eacabef109
Aug. 07, 2026
Action Type Old Value New Value Added Affected [{'vendor': 'Vestel', 'modules': ['Smart Center', 'browserseturl command'], 'product': 'Telefunken TE24553B45V2DZ Smart TV', 'versions': [{'status': 'affected', 'version': 'V2.78.0.0'}, {'status': 'unaffected', 'version': 'V2.85.2.0'}], 'platforms': ['Vestel MB181 / Voltron181 / TiVo OS'], 'defaultStatus': 'unknown'}] Added Description An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0. Added CVSS V4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-918 Added Reference https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4 Added Reference https://vestelinternational.com/security-advisories