7.1
HIGH CVSS 4.0
CVE-2026-15570
Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command
Description

An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.

INFO

Published Date :

Aug. 7, 2026, 2:16 p.m.

Last Modified :

Aug. 7, 2026, 3:16 p.m.

Remotely Exploit :

No

Source :

5431be70-064b-4f6a-be51-69eacabef109
Affected Products

The following products are affected by CVE-2026-15570 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 134c704f-9b21-4f2e-91b3-4a467353bcc0
CVSS 4.0 HIGH 5431be70-064b-4f6a-be51-69eacabef109
CVSS 4.0 HIGH 5431be70-064b-4f6a-be51-69eacabef109
Solution
Update firmware to patch the vulnerability and prevent internal service access.
  • Update firmware to version V2.85.2.0 or later.
  • Verify that the browserseturl command restrictions are enforced.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2026-15570.

URL Resource
https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4
https://vestelinternational.com/security-advisories
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-15570 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2026-15570 weaknesses.

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-15570 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-15570 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by 134c704f-9b21-4f2e-91b3-4a467353bcc0

    Aug. 07, 2026

    Action Type Old Value New Value
    Added SSVC {'id': 'CVE-2026-15570', 'role': 'CISA Coordinator', 'options': [{'exploitation': 'none'}, {'automatable': 'no'}, {'technicalImpact': 'partial'}], 'version': '2.0.3', 'timestamp': '2026-08-07T14:25:53.841501Z'}
  • New CVE Received by 5431be70-064b-4f6a-be51-69eacabef109

    Aug. 07, 2026

    Action Type Old Value New Value
    Added Affected [{'vendor': 'Vestel', 'modules': ['Smart Center', 'browserseturl command'], 'product': 'Telefunken TE24553B45V2DZ Smart TV', 'versions': [{'status': 'affected', 'version': 'V2.78.0.0'}, {'status': 'unaffected', 'version': 'V2.85.2.0'}], 'platforms': ['Vestel MB181 / Voltron181 / TiVo OS'], 'defaultStatus': 'unknown'}]
    Added Description An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.
    Added CVSS V4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CWE CWE-918
    Added Reference https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4
    Added Reference https://vestelinternational.com/security-advisories
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.