8.2
HIGH CVSS 3.1
CVE-2026-17100
Power System Out-of-bounds Write
Description

Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1, and OP940.00 - OP940.81 is affected by a vulnerability in the service processor mailbox interface. An attacker with authenticated service-level access to the BMC/FSP can exploit this vulnerability, allowing arbitrary code to be executed in the host firmware runtime, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact to the managed system.

INFO

Published Date :

Aug. 19, 2026, 7:17 p.m.

Last Modified :

Aug. 19, 2026, 7:17 p.m.

Remotely Exploit :

No
Affected Products

The following products are affected by CVE-2026-17100 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 HIGH 9a959283-ebb5-44b6-b705-dcc2bbced522
CVSS 3.1 HIGH [email protected]
CVSS 3.1 HIGH MITRE-CVE
Solution
Update IBM Power Firmware to the latest version to fix arbitrary code execution vulnerability.
  • Update IBM Power Firmware to the latest version.
  • Apply vendor-supplied security patches.
  • Restrict service-level access to BMC/FSP.
  • Monitor system logs for suspicious activity.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2026-17100.

URL Resource
https://www.ibm.com/support/pages/node/7283236
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-17100 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2026-17100 weaknesses.

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-17100 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-17100 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Aug. 19, 2026

    Action Type Old Value New Value
    Added Affected [{'cpes': ['cpe:2.3:o:ibm:power_firmware:fw1120.00:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw1110.00:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw1110.30:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw1060.00:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw1060.80:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw950.00:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:fw950.h2:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:op940.00:*:*:*:*:*:*:*', 'cpe:2.3:o:ibm:power_firmware:op940.a1:*:*:*:*:*:*:*'], 'vendor': 'IBM', 'product': 'Power Systems Firmware', 'versions': [{'status': 'affected', 'version': 'FW1120.00'}, {'status': 'affected', 'version': 'FW1110.00', 'versionType': 'semver', 'lessThanOrEqual': 'FW1110.30'}, {'status': 'affected', 'version': 'FW1060.00', 'versionType': 'semver', 'lessThanOrEqual': 'FW1060.80'}, {'status': 'affected', 'version': 'FW950.00', 'versionType': 'semver', 'lessThanOrEqual': 'FW950.H2'}, {'status': 'affected', 'version': 'OP940.00', 'versionType': 'semver', 'lessThanOrEqual': 'OP940.a1'}, {'status': 'affected', 'version': 'OP940.00', 'versionType': 'semver', 'lessThanOrEqual': 'OP940.81'}]}]
    Added Description Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1, and OP940.00 - OP940.81 is affected by a vulnerability in the service processor mailbox interface. An attacker with authenticated service-level access to the BMC/FSP can exploit this vulnerability, allowing arbitrary code to be executed in the host firmware runtime, giving full control over the managed system, resulting in a confidentiality, integrity, and availability impact to the managed system.
    Added CVSS V3.1 AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
    Added CWE CWE-787
    Added Reference https://www.ibm.com/support/pages/node/7283236
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.