Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check
Description

The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.

INFO

Published Date :

Aug. 5, 2026, 9:16 p.m.

Last Modified :

Aug. 5, 2026, 9:16 p.m.

Remotely Exploit :

No
Affected Products

The following products are affected by CVE-2026-17583 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 HIGH 7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
CVSS 3.1 HIGH [email protected]
CVSS 4.0 HIGH 7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
CVSS 4.0 HIGH [email protected]
Solution
Sanitize or validate .fsa/.hid files to prevent data tampering.
  • Validate integrity of .fsa/.hid files.
  • Implement input validation for file content.
  • Ensure file content cannot be maliciously altered.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2026-17583.

URL Resource
https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf
https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01
https://www.cve.org/CVERecord?id=CVE-2026-17583
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-17583 is associated with the following CWEs:

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-17583 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-17583 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Aug. 05, 2026

    Action Type Old Value New Value
    Added Affected [{'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems 3500/3500xL Series Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '4.0.2'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems 3730/3730xL Series Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '5.0.2'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '1.2.5'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems SeqStudio Flex Series Instrument Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '1.2.0'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems GeneMapper ID-X Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '1.7.3'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'Applied Biosystems 3130 Series Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '4.1'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'ABI PRISM 3100/3100-Avant Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '2.0'}], 'defaultStatus': 'unaffected'}, {'vendor': 'Thermo Fisher', 'product': 'ABI PRISM 310 Data Collection Software', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'custom', 'lessThanOrEqual': '3.1'}], 'defaultStatus': 'unaffected'}]
    Added Description The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
    Added CVSS V4.0 AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CVSS V3.1 AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
    Added CWE CWE-353
    Added Reference https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf
    Added Reference https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01
    Added Reference https://www.cve.org/CVERecord?id=CVE-2026-17583
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.