8.4
HIGH CVSS 4.0
CVE-2026-19003
MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings
Description

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

INFO

Published Date :

Aug. 12, 2026, 10:17 p.m.

Last Modified :

Aug. 12, 2026, 10:17 p.m.

Remotely Exploit :

No
Affected Products

The following products are affected by CVE-2026-19003 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 HIGH a39b4221-9bd0-4244-95fc-f3e2e07f1deb
CVSS 3.1 HIGH [email protected]
CVSS 4.0 HIGH a39b4221-9bd0-4244-95fc-f3e2e07f1deb
CVSS 4.0 HIGH [email protected]
Solution
Update the MongoDB BI Connector ODBC Driver to a version that addresses buffer capacity calculation issues.
  • Update the MongoDB BI Connector ODBC Driver.
  • Ensure buffer calculations are validated.
  • Limit file path string length.
  • Review dialog input handling.
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2026-19003.

URL Resource
https://github.com/mongodb/mongo-bi-connector-odbc-driver/releases/tag/v1.4.9
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-19003 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2026-19003 weaknesses.

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-19003 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-19003 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Aug. 12, 2026

    Action Type Old Value New Value
    Added Affected [{'repo': 'https://github.com/mongodb/mongo-bi-connector-odbc-driver', 'vendor': 'MongoDB', 'product': 'BI Connector ODBC Driver', 'versions': [{'status': 'affected', 'version': '1.0.0', 'lessThan': '1.4.9', 'versionType': 'semver'}], 'platforms': ['Windows', '64 bit', '32 bit'], 'defaultStatus': 'unaffected'}]
    Added Description A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.
    Added CVSS V4.0 AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
    Added CVSS V3.1 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
    Added CWE CWE-121
    Added Reference https://github.com/mongodb/mongo-bi-connector-odbc-driver/releases/tag/v1.4.9
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.