CVE-2026-19739
Bluetooth LE controller leaks a retained RX node when an unexpected LL Control PDU arrives during a Connection Update
Description
The Bluetooth Link Layer control procedure code in subsys/bluetooth/controller/ll_sw/ull_llcp_conn_upd.c retains the received RX node while a Connection Update / Connection Parameter procedure waits for its instant, so the node can later carry the host notification (llcp_rx_node_retain(), which marks it NODE_RX_TYPE_RETAIN and thereby suppresses the normal recycling in ull.c). The default: arm of llcp_rp_cu_rx() and llcp_lp_cu_rx() — the "invalid PDU, terminate the connection" path — completed the procedure without releasing that retained node. llcp_rr_check_done() then dequeued and freed the procedure context with ctx->node_ref.rx still pointing at the retained node, dropping the last reference to it. A peer device in radio range can reach this without pairing, bonding, or encryption. Against a peripheral, the peer sends a well-formed LL_CONNECTION_UPDATE_IND with an instant a few connection events in the future (the node is retained and the procedure enters RP_CU_STATE_WAIT_INSTANT), then, before the instant is reached, sends any other LL Control PDU such as LL_LENGTH_REQ. ull_cp_rx() routes that PDU into the active remote Connection Update procedure, which takes the invalid-PDU path. The central role is reachable symmetrically after accepting an LL_CONNECTION_PARAM_REQ, and the local-procedure variant is reachable with LL_REJECT_IND. With CONFIG_BT_CTLR_ASSERT_DEBUG enabled (its default), the resulting state violates the invariant asserted in llcp_rr_check_done(), so the two-PDU sequence produces an immediate fatal error in the controller. With those asserts disabled, each occurrence permanently loses one node from the controller's small fixed RX pool (sized from CONFIG_BT_CTLR_RX_BUFFERS, which defaults to 1); repeating the sequence across reconnections exhausts the pool, after which the link-layer receive path operates on a NULL node. The impact is an unauthenticated, remotely triggerable denial of service persisting until reboot; there is no memory-disclosure or memory-corruption consequence, since the leaked node simply becomes unreachable.
INFO
Published Date :
Oct. 11, 2026, 5:15 p.m.
Last Modified :
Oct. 11, 2026, 5:15 p.m.
Remotely Exploit :
No
Source :
zephyr
Affected Products
The following products are affected by CVE-2026-19739
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 3.1 | MEDIUM | e2e69745-5e70-4e92-8431-deb5529a81ad | ||||
| CVSS 3.1 | MEDIUM | MITRE-CVE |
Solution
- Update the Bluetooth controller firmware.
- Ensure correct node management in LLCP.
- Review connection update procedure logic.
- Apply the provided patch for ull_llcp_conn_upd.c.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-19739 vulnerability anywhere in the article.