CVE-2026-45916
power: supply: sbs-battery: Fix use-after-free in power_supply_changed()
Description
In the Linux kernel, the following vulnerability has been resolved: power: supply: sbs-battery: Fix use-after-free in power_supply_changed() Using the `devm_` variant for requesting IRQ _before_ the `devm_` variant for allocating/registering the `power_supply` handle, means that the `power_supply` handle will be deallocated/unregistered _before_ the interrupt handler (since `devm_` naturally deallocates in reverse allocation order). This means that during removal, there is a race condition where an interrupt can fire just _after_ the `power_supply` handle has been freed, *but* just _before_ the corresponding unregistration of the IRQ handler has run. This will lead to the IRQ handler calling `power_supply_changed()` with a freed `power_supply` handle. Which usually crashes the system or otherwise silently corrupts the memory... Note that there is a similar situation which can also happen during `probe()`; the possibility of an interrupt firing _before_ registering the `power_supply` handle. This would then lead to the nasty situation of using the `power_supply` handle *uninitialized* in `power_supply_changed()`. Fix this racy use-after-free by making sure the IRQ is requested _after_ the registration of the `power_supply` handle. Keep the old behavior of just printing a warning in case of any failures during the IRQ request and finishing the probe successfully.
INFO
Published Date :
May 27, 2026, 2:17 p.m.
Last Modified :
May 27, 2026, 2:48 p.m.
Remotely Exploit :
No
Source :
416baaa9-dc9f-4396-8d5f-8c081fb06d67
Solution
- Request IRQ after allocating the power_supply handle.
- Ensure interrupt handlers are registered correctly.
- Review resource management order in drivers.
- Apply the latest kernel updates.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-45916.
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-45916 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-45916
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-45916 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-45916 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by 416baaa9-dc9f-4396-8d5f-8c081fb06d67
May. 27, 2026
Action Type Old Value New Value Added Description In the Linux kernel, the following vulnerability has been resolved: power: supply: sbs-battery: Fix use-after-free in power_supply_changed() Using the `devm_` variant for requesting IRQ _before_ the `devm_` variant for allocating/registering the `power_supply` handle, means that the `power_supply` handle will be deallocated/unregistered _before_ the interrupt handler (since `devm_` naturally deallocates in reverse allocation order). This means that during removal, there is a race condition where an interrupt can fire just _after_ the `power_supply` handle has been freed, *but* just _before_ the corresponding unregistration of the IRQ handler has run. This will lead to the IRQ handler calling `power_supply_changed()` with a freed `power_supply` handle. Which usually crashes the system or otherwise silently corrupts the memory... Note that there is a similar situation which can also happen during `probe()`; the possibility of an interrupt firing _before_ registering the `power_supply` handle. This would then lead to the nasty situation of using the `power_supply` handle *uninitialized* in `power_supply_changed()`. Fix this racy use-after-free by making sure the IRQ is requested _after_ the registration of the `power_supply` handle. Keep the old behavior of just printing a warning in case of any failures during the IRQ request and finishing the probe successfully. Added Reference https://git.kernel.org/stable/c/14d4dee5d8fb361bfff275832087254beab66d72 Added Reference https://git.kernel.org/stable/c/2078830c32d1e49ac942c6f8c21f35c806ae5e94 Added Reference https://git.kernel.org/stable/c/8010b745b436c3e1ca5dd960aa29fa3e0f6d8841 Added Reference https://git.kernel.org/stable/c/82d3eb97a976c9d56bb92b241397610e57a9c629 Added Reference https://git.kernel.org/stable/c/861dda7a9074c0ff67788928165ae39d7f647491 Added Reference https://git.kernel.org/stable/c/8d59cf3887fbabacef53bfba473e33e8a8d9d07b Added Reference https://git.kernel.org/stable/c/ca7dd71773e4e050b0fb98768b7eae60f8d1f38b Added Reference https://git.kernel.org/stable/c/f1f472b14ad56104ba228b8fbec60d5b21829913