nginx ignition has TOTP Reuse During Validity Window
Description

nginx ignition is a user interface for the nginx web server. In versions 2.33.0 through 2.35.0, any user that has enabled the OTP 2FA can have their TOTP reused during the standard 30 second validity window. Version 2.35.1 patches the issue.

INFO

Published Date :

Sept. 21, 2026, 3:17 p.m.

Last Modified :

Sept. 21, 2026, 3:17 p.m.

Remotely Exploit :

Yes !
Affected Products

The following products are affected by CVE-2026-61630 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

No affected product recoded yet

CVSS Scores
The Common Vulnerability Scoring System is a standardized framework for assessing the severity of vulnerabilities in software and systems. We collect and displays CVSS scores from various sources for each CVE.
Score Version Severity Vector Exploitability Score Impact Score Source
CVSS 3.1 MEDIUM MITRE-CVE
CVSS 3.1 MEDIUM [email protected]
Solution
Update nginx ignition to version 2.35.1 to fix OTP reuse vulnerability.
  • Update nginx ignition to version 2.35.1.
  • Verify OTP 2FA is functioning correctly.
  • Review access logs for suspicious activity.
References to Advisories, Solutions, and Tools
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2026-61630 is associated with the following CWEs:

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2026-61630 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2026-61630 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • New CVE Received by [email protected]

    Sep. 21, 2026

    Action Type Old Value New Value
    Added Description nginx ignition is a user interface for the nginx web server. In versions 2.33.0 through 2.35.0, any user that has enabled the OTP 2FA can have their TOTP reused during the standard 30 second validity window. Version 2.35.1 patches the issue.
    Added CVSS V3.1 AV:N/AC:H/PR:H/UI:R/S:U/C:H/I:N/A:N
    Added CWE CWE-287
    Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/61xxx/CVE-2026-61630.json">CVE-2026-61630</a>
    Added Reference https://github.com/lucasdillmann/nginx-ignition/commit/1cbfae0296f1b186158f5a294ec484060e00102e
    Added Reference https://github.com/lucasdillmann/nginx-ignition/commit/8d35e1eb5dd6a40fef94a45511fe08b0603af107
    Added Reference https://github.com/lucasdillmann/nginx-ignition/security/advisories/GHSA-hf33-q6cf-c66f