CVE-2026-73158
cti-transmute Saved Graph Configuration Allows Stored Cross-Site Scripting via svgIcon
Description
Affected versions of cti-transmute insufficiently validate saved graph configuration data. Graph configurations can contain style properties that are later consumed by Pivotick, and Pivotick interprets svgIcon as HTML. Because saved configurations may be created by one user and later displayed to other users—including administrators—a malicious user could store a crafted svgIcon value that executes script in another viewer’s browser. The fix introduces a strict configuration schema on both the server and client. Only known properties are accepted, style entries are limited to shape, color, and size, and dangerous properties such as svgIcon and iconClass are explicitly rejected. Existing stored configurations are also sanitized when listed and again before being applied in the browser.
INFO
Published Date :
Aug. 11, 2026, 9:17 a.m.
Last Modified :
Aug. 11, 2026, 9:17 a.m.
Remotely Exploit :
Yes !
Source :
5a6e4751-2f3f-4070-9419-94fb35b644e8
Affected Products
The following products are affected by CVE-2026-73158
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 4.0 | MEDIUM | 5a6e4751-2f3f-4070-9419-94fb35b644e8 | ||||
| CVSS 4.0 | MEDIUM | 5a6e4751-2f3f-4070-9419-94fb35b644e8 |
Solution
- Apply schema validation to graph configurations.
- Reject dangerous properties like svgIcon.
- Sanitize existing stored configurations.
- Update to the latest secure version.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-73158.
| URL | Resource |
|---|---|
| https://github.com/MISP/cti-transmute/commit/9b317587fa4ec11b6f72c2d1d8b98a686537b4fb |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-73158 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-73158
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-73158 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-73158 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by 5a6e4751-2f3f-4070-9419-94fb35b644e8
Aug. 11, 2026
Action Type Old Value New Value Added Affected [{'repo': 'https://github.com/MISP/cti-transmute', 'vendor': 'MISP', 'product': 'cti-transmute', 'versions': [{'status': 'affected', 'version': '0', 'versionType': 'semver', 'lessThanOrEqual': '1.4.0'}], 'defaultStatus': 'unaffected'}] Added Description Affected versions of cti-transmute insufficiently validate saved graph configuration data. Graph configurations can contain style properties that are later consumed by Pivotick, and Pivotick interprets svgIcon as HTML. Because saved configurations may be created by one user and later displayed to other users—including administrators—a malicious user could store a crafted svgIcon value that executes script in another viewer’s browser. The fix introduces a strict configuration schema on both the server and client. Only known properties are accepted, style entries are limited to shape, color, and size, and dangerous properties such as svgIcon and iconClass are explicitly rejected. Existing stored configurations are also sanitized when listed and again before being applied in the browser. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-79 Added CWE CWE-20 Added Reference https://github.com/MISP/cti-transmute/commit/9b317587fa4ec11b6f72c2d1d8b98a686537b4fb