CVE-2026-80146
Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read
Description
Lantronix SLC8000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
INFO
Published Date :
Sept. 22, 2026, 4:18 p.m.
Last Modified :
Sept. 22, 2026, 4:18 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2026-80146
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 3.1 | CRITICAL | 83251b91-4cc7-4094-a5c7-464a1b83ea10 | ||||
| CVSS 3.1 | CRITICAL | [email protected] | ||||
| CVSS 4.0 | CRITICAL | 83251b91-4cc7-4094-a5c7-464a1b83ea10 | ||||
| CVSS 4.0 | CRITICAL | [email protected] |
Solution
- Update firmware to v9.7.0.2 or later for SLC8000.
- Update firmware to v9.7.0.1 or later for EMG8500/EMG7500.
- Update firmware for SLB882/SLCx-03/SLCx-02.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-80146.
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-80146 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-80146
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-80146 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-80146 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Sep. 22, 2026
Action Type Old Value New Value Added Description Lantronix SLC8000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CVSS V3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H Added CWE CWE-121 Added Affected New affected value received. <a href="https://github.com/CVEProject/cvelistV5/blob/main/cves/2026/80xxx/CVE-2026-80146.json">CVE-2026-80146</a> Added Reference https://revrb.net/2026/09/21/revrb-lantern.html Added Reference https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ Added Reference https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ Added Reference https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ Added Reference https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-read