Uncaught exception vulnerability in Suprema's BioStar
Description
An unhandled exception in Suprema BioStar 2 (Server), versions 2.9.8, 2.9.10, and 2.9.11, that allows an unauthenticated remote attacker to cause a denial of service (DoS) by sending HTTP POST requests to the ‘/api/migration’ endpoint. This request triggers a failure that halts critical processes, leaving the system offline until the services or server are manually restarted. As a result, access control readers cease to function, and potential failures may occur in third-party integrations. Since the exploit requires no privileges or user interaction and is trivial to automate, the impact on availability is high, and the effect extends to interconnected systems.
INFO
Published Date :
May 29, 2026, 1:16 p.m.
Last Modified :
May 29, 2026, 1:16 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2026-9509
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 4.0 | HIGH | [email protected] |
Solution
- Update Suprema BioStar 2 to a patched version.
- Apply vendor security updates promptly.
- Monitor system availability after updates.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-9509.
| URL | Resource |
|---|---|
| https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-supremas-biostar |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-9509 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-9509
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-9509 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-9509 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
May. 29, 2026
Action Type Old Value New Value Added Description An unhandled exception in Suprema BioStar 2 (Server), versions 2.9.8, 2.9.10, and 2.9.11, that allows an unauthenticated remote attacker to cause a denial of service (DoS) by sending HTTP POST requests to the ‘/api/migration’ endpoint. This request triggers a failure that halts critical processes, leaving the system offline until the services or server are manually restarted. As a result, access control readers cease to function, and potential failures may occur in third-party integrations. Since the exploit requires no privileges or user interaction and is trivial to automate, the impact on availability is high, and the effect extends to interconnected systems. Added CVSS V4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-248 Added Reference https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-supremas-biostar