Latest CVE Feed
-
8.5
HIGHCVE-2025-69414
Plex Media Server (PMS) through 1.42.2.10156 allows retrieval of a permanent access token via a /myplex/account call with a transient access token.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
5.0
MEDIUMCVE-2025-69417
In the plex.tv backend for Plex Media Server (PMS) through 2025-12-31, a non-server device token can retrieve share tokens (intended for unrelated access) via a shared_servers endpoint.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
5.0
MEDIUMCVE-2025-69416
In the plex.tv backend for Plex Media Server (PMS) through 2025-12-31, a non-server device token can retrieve other tokens (intended for unrelated access) via clients.plex.tv/devices.xml.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
5.3
MEDIUMCVE-2025-12519
Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configu... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
8.7
HIGHCVE-2025-64124
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): before 2.5.1.... Read more
Affected Products :- Published: Jan. 03, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
7.7
HIGHCVE-2025-5591
Kentico Xperience 13 is vulnerable to a stored cross-site scripting attack via a form component, allowing an attacker to hijack a victim user’s session and perform actions in their security context.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
6.9
MEDIUMCVE-2025-15455
A flaw has been found in bg5sbk MiniCMS up to 1.8. Impacted is the function delete_page of the file /minicms/mc-admin/page.php of the component File Recovery Request Handler. This manipulation causes improper authentication. The attack is possible to be c... Read more
Affected Products : minicms- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
5.3
MEDIUMCVE-2026-21635
An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
7.2
HIGHCVE-2025-5965
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Bac... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
6.9
MEDIUMCVE-2025-34171
CasaOS versions up to and including 0.4.15 expose multiple unauthenticated endpoints that allow remote attackers to retrieve sensitive configuration files and system debug information. The /v1/users/image endpoint can be abused with a user-controlled path... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
-
9.4
CRITICALCVE-2025-64123
Unintended Proxy or Intermediary vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Network Boundary Bridging.This issue affects Multi-Stack Controller (MSC): through and including release 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
7.5
HIGHCVE-2025-67158
An authentication bypass in the /cgi-bin/jvsweb.cgi endpoint of Revotech I6032W-FHW v1.0.0014 - 20210517 allows attackers to access sensitive information and escalate privileges via a crafted HTTP request.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
4.3
MEDIUMCVE-2025-65922
PLANKA 2.0.0 lacks X-Frame-Options and CSP frame-ancestors headers, allowing the application to be embedded within malicious iframes. While this does not lead to unintended modification of projects or tasks, it exposes users to Phishing attacks. Attackers... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
7.2
HIGHCVE-2025-64122
Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Signature Spoofing by Key Theft.This issue affects Multi-Stack Controller (MSC): through 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cryptography
-
7.5
HIGHCVE-2025-67160
An issue in Vatilon v1.12.37-20240124 allows attackers to access sensitive directories and files via a directory traversal.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal
-
6.5
MEDIUMCVE-2023-51513
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in INTINITUM FORM Geo Controller allows DOM-Based XSS.This issue affects Geo Controller: from n/a through 8.5.2.... Read more
Affected Products : geo_controller- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
9.4
CRITICALCVE-2025-64120
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
9.3
CRITICALCVE-2025-64119
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
6.5
MEDIUMCVE-2026-21634
A malicious actor with access to the adjacent network could overflow the UniFi Protect Application (Version 6.1.79 and earlier) discovery protocol causing it to restart. Affected Products: UniFi Protect Application (Version 6.1.79 and earlier). ... Read more
Affected Products : unifi_protect- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Denial of Service
-
9.2
CRITICALCVE-2026-21440
AdonisJS is a TypeScript-first web framework. A Path Traversal vulnerability in AdonisJS multipart file handling may allow a remote attacker to write arbitrary files to arbitrary locations on the server filesystem. This impacts @adonisjs/bodyparser throug... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal